NSN 5905-00-056-9611 of Resistor Fixed Wire Wound Induct - Parts Details
Alternative NSN: 5905000569611 |
Item Name: Resistor Fixed Wire Wound Induct |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5905 Resistors |
NIIN: 000569611 |
NCB Code: USA (00) |
Manufacturers: Westinghouse Electric Corp , Vishay Dale Electronics Inc , Tepro Of Florida Inc |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers 1JA4264H67, RS10-15K1, TS10W15K1 under NSN 5905-00-056-9611 of Resistor Fixed Wire Wound Induct manufactured by Westinghouse Electric Corp, Vishay Dale Electronics Inc, Tepro Of Florida Inc.
Federal Supply Class of NSN 5905-00-056-9611 is FSC 5905 contains part details of Resistors. Quote for your desired part numbers.
Part Number's List for NSN 5905-00-056-9611, 5905000569611
Characteristics Data of NSN 5905000569611MRC Criteria Characteristic AAPE TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS -30.0 TO 30.0 AAPP ELECTRICAL RESISTANCE 15.000 KILOHMS AAPQ RESISTANCE TOLERANCE IN PERCENT -0.100 TO 0.100 AAQF AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER 25.0 AAQG AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER 275.0 AAQH TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS -55.0 TO 275.0 AAQZ INCLOSURE METHOD ENCAPSULATED AARB TERMINAL TYPE WIRE LEAD AARG RELIABILITY INDICATOR NOT ESTABLISHED ABJT TERMINAL LENGTH 1.500 INCHES MINIMUM ABPM BODY DIAMETER 0.344 INCHES MINIMUM AND 0.406 INCHES MAXIMUM ADAQ BODY LENGTH 1.718 INCHES MINIMUM AND 1.842 INCHES MAXIMUM AEFB POWER DISSIPATION RATING IN WATTS 10.000 FREE AIR STYL STYLE DESIGNATOR AXIAL TERMINAL EACH END
MRC | Criteria | Characteristic |
---|---|---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -30.0 TO 30.0 |
AAPP | ELECTRICAL RESISTANCE | 15.000 KILOHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -0.100 TO 0.100 |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 25.0 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 275.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 275.0 |
AAQZ | INCLOSURE METHOD | ENCAPSULATED |
AARB | TERMINAL TYPE | WIRE LEAD |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 1.500 INCHES MINIMUM |
ABPM | BODY DIAMETER | 0.344 INCHES MINIMUM AND 0.406 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 1.718 INCHES MINIMUM AND 1.842 INCHES MAXIMUM |
AEFB | POWER DISSIPATION RATING IN WATTS | 10.000 FREE AIR |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |