NSN 5905-00-225-4300 of Resistor Fixed Wire Wound Induct - Parts Details
Alternative NSN: 5905002254300 |
Item Name: Resistor Fixed Wire Wound Induct |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5905 Resistors |
NIIN: 002254300 |
NCB Code: USA (00) |
Manufacturers: Trw Inc , Butler National Corp , Thales Communications Inc |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers BWH2-2R20HMP0RM5, B204073-0007, 858099-8033, 858099-0033, 204073-0007 under NSN 5905-00-225-4300 of Resistor Fixed Wire Wound Induct manufactured by Trw Inc, Butler National Corp, Thales Communications Inc.
Federal Supply Class of NSN 5905-00-225-4300 is FSC 5905 contains part details of Resistors. Quote for your desired part numbers.
Part Number's List for NSN 5905-00-225-4300, 5905002254300
-
Part No Manufacturer Item Name QTY RFQ BWH2-2R20HMP0RM5 Trw Inc resistor fixed wire wound induct Avl RFQ B204073-0007 Butler National Corp resistor fixed wire wound induct Avl RFQ 858099-8033 Thales Communications Inc resistor fixed wire wound induct Avl RFQ 858099-0033 Thales Communications Inc resistor fixed wire wound induct Avl RFQ 204073-0007 Butler National Corp resistor fixed wire wound induct Avl RFQ
Characteristics Data of NSN 5905002254300MRC Criteria Characteristic AAPE TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS -400.0 TO 400.0 AAPP ELECTRICAL RESISTANCE 2.200 OHMS AAPQ RESISTANCE TOLERANCE IN PERCENT -5.000 TO 5.000 AAQF AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER 25.0 AAQG AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER 350.0 AAQH TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS -55.0 TO 350.0 AAQZ INCLOSURE METHOD ENCAPSULATED AARB TERMINAL TYPE WIRE LEAD AARG RELIABILITY INDICATOR NOT ESTABLISHED ABPM BODY DIAMETER 0.188 INCHES NOMINAL ADAQ BODY LENGTH 0.500 INCHES NOMINAL AEFB POWER DISSIPATION RATING IN WATTS 3.000 FREE AIR STYL STYLE DESIGNATOR AXIAL TERMINAL EACH END TEST TEST DATA DOCUMENT 81349-MILR26/4 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA
MRC | Criteria | Characteristic |
---|---|---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -400.0 TO 400.0 |
AAPP | ELECTRICAL RESISTANCE | 2.200 OHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -5.000 TO 5.000 |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 25.0 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 350.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 350.0 |
AAQZ | INCLOSURE METHOD | ENCAPSULATED |
AARB | TERMINAL TYPE | WIRE LEAD |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABPM | BODY DIAMETER | 0.188 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.500 INCHES NOMINAL |
AEFB | POWER DISSIPATION RATING IN WATTS | 3.000 FREE AIR |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |
TEST | TEST DATA DOCUMENT | 81349-MILR26/4 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA |