NSN 5905-00-406-9196 of Resistor Thermal - Parts Details
Alternative NSN: 5905004069196 |
Item Name: Resistor Thermal |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5905 Resistors |
NIIN: 004069196 |
NCB Code: USA (00) |
Manufacturers: Texas Instrument Inc , Rtie Holdings Llc , Triumph Actuation Systems |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers TM1-8-222K, TM1-8-2200, TM1-8 22000HMP0RM10PCT, DS125-222K, 215-27583-2 under NSN 5905-00-406-9196 of Resistor Thermal manufactured by Texas Instrument Inc, Rtie Holdings Llc, Triumph Actuation Systems.
Federal Supply Class of NSN 5905-00-406-9196 is FSC 5905 contains part details of Resistors. Quote for your desired part numbers.
Part Number's List for NSN 5905-00-406-9196, 5905004069196
-
Part No Manufacturer Item Name QTY RFQ TM1-8-222K Texas Instrument Inc resistor thermal Avl RFQ TM1-8-2200 Texas Instrument Inc resistor thermal Avl RFQ TM1-8 22000HMP0RM10PCT Texas Instrument Inc resistor thermal Avl RFQ DS125-222K Rtie Holdings Llc resistor thermal Avl RFQ 215-27583-2 Triumph Actuation Systems resistor thermal Avl RFQ
Characteristics Data of NSN 5905004069196MRC Criteria Characteristic AARG RELIABILITY INDICATOR NOT ESTABLISHED ABDN TERMINAL SURFACE TREATMENT TIN ABJT TERMINAL LENGTH 1.375 INCHES MINIMUM AND 1.625 INCHES MAXIMUM ADAQ BODY LENGTH 0.391 INCHES MINIMUM AND 0.421 INCHES MAXIMUM ADAR BODY OUTSIDE DIAMETER 0.125 INCHES MINIMUM AND 0.135 INCHES MAXIMUM AEBT TERMINAL DIAMETER 0.025 INCHES NOMINAL AEHX MAXIMUM POWER DISSIPATION RATING 125.00 MILLIWATTS AEHY AMBIENT TEMP AT FULL RATED POWER 100.0 DEG CELSIUS AEHZ MAXIMUM OPERATING TEMP 150.0 DEG CELSIUS AEJA THERMAL TIME CONSTANT IN SECONDS 34.8 AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER -15.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER -55.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER 100.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER 125.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER 50.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 1.1 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 1.6 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 2.7 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 3.7 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 4.3 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT AEJF RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT -12.0/+12.0 3RD RESISTANCE-TEMPERATURE POINT AEJF RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT -14.0/+14.0 2ND RESISTANCE-TEMPERATURE POINT AEJF RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT -17.0/+17.0 4TH RESISTANCE-TEMPERATURE POINT AEJF RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT -20.0/+20.0 1ST RESISTANCE-TEMPERATURE POINT AEJF RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT -20.0/+20.0 5TH RESISTANCE-TEMPERATURE POINT AKNA INCLOSURE TYPE ENCAPSULATED CQWD III ZERO POWER RESISTANCE 2.200 KILOHMS CRQJ ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP -10.0/+10.0 CTGT REFERENCE TEMP IN DEG CELSIUS 25.0 STYL STYLE DESIGNATOR ROD TEST TEST DATA DOCUMENT 80378-215-27483 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DR TTQY TERMINAL TYPE AND QUANTITY 2 WIRE LEAD
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABDN | TERMINAL SURFACE TREATMENT | TIN |
ABJT | TERMINAL LENGTH | 1.375 INCHES MINIMUM AND 1.625 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.391 INCHES MINIMUM AND 0.421 INCHES MAXIMUM |
ADAR | BODY OUTSIDE DIAMETER | 0.125 INCHES MINIMUM AND 0.135 INCHES MAXIMUM |
AEBT | TERMINAL DIAMETER | 0.025 INCHES NOMINAL |
AEHX | MAXIMUM POWER DISSIPATION RATING | 125.00 MILLIWATTS |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 100.0 DEG CELSIUS |
AEHZ | MAXIMUM OPERATING TEMP | 150.0 DEG CELSIUS |
AEJA | THERMAL TIME CONSTANT IN SECONDS | 34.8 |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -15.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -55.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.1 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.6 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 2.7 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 3.7 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 4.3 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.0/+12.0 3RD RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -14.0/+14.0 2ND RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -17.0/+17.0 4TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -20.0/+20.0 1ST RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -20.0/+20.0 5TH RESISTANCE-TEMPERATURE POINT |
AKNA | INCLOSURE TYPE | ENCAPSULATED |
CQWD | III ZERO POWER RESISTANCE | 2.200 KILOHMS |
CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0/+10.0 |
CTGT | REFERENCE TEMP IN DEG CELSIUS | 25.0 |
STYL | STYLE DESIGNATOR | ROD |
TEST | TEST DATA DOCUMENT | 80378-215-27483 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DR |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |