ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers 6127-314-063, 352250001012 under NSN 5905-00-834-6456 of Resistor Fixed Film manufactured by Saab Scania Ab Data Saab Div Mil, Thales Nederland.
Federal Supply Class of NSN 5905-00-834-6456 is FSC 5905 contains part details of Resistors. Quote for your desired part numbers.
Part Number's List for NSN 5905-00-834-6456, 5905008346456
-
Part No Manufacturer Item Name QTY RFQ 6127-314-063 Saab Scania Ab Data Saab Div Mil resistor fixed film Avl RFQ 352250001012 Thales Nederland resistor fixed film Avl RFQ
Characteristics Data of NSN 5905008346456MRC Criteria Characteristic AAPE TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS -50.0/+50.0 AAPP ELECTRICAL RESISTANCE 56.200 KILOHMS AAPQ RESISTANCE TOLERANCE IN PERCENT -1.000/+1.000 AAQF AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER 125.0 AAQG AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER 175.0 AAQH TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS -55.0/+175.0 AAQZ INCLOSURE METHOD ENCAPSULATED ABPM BODY DIAMETER 0.125 INCHES NOMINAL ADAQ BODY LENGTH 0.375 INCHES NOMINAL AEFB POWER DISSIPATION RATING IN WATTS 0.125 FREE AIR STYL STYLE DESIGNATOR AXIAL TERMINAL EACH END TEST TEST DATA DOCUMENT 81349-MIL-R-10509 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTI ZZZK SPECIFICATION/STANDARD DATA 81349-MIL-R-10509/1 GOVERNMENT SPECIFICATION AARB TERMINAL TYPE WIRE LEAD AARG RELIABILITY INDICATOR NOT ESTABLISHED
MRC | Criteria | Characteristic |
---|---|---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -50.0/+50.0 |
AAPP | ELECTRICAL RESISTANCE | 56.200 KILOHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -1.000/+1.000 |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 125.0 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 175.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0/+175.0 |
AAQZ | INCLOSURE METHOD | ENCAPSULATED |
ABPM | BODY DIAMETER | 0.125 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.375 INCHES NOMINAL |
AEFB | POWER DISSIPATION RATING IN WATTS | 0.125 FREE AIR |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-10509 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTI |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-10509/1 GOVERNMENT SPECIFICATION |
AARB | TERMINAL TYPE | WIRE LEAD |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |