NSN 5905-00-883-1548 of Resistor Thermal - Parts Details
Alternative NSN: 5905008831548 |
Item Name: Resistor Thermal |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5905 Resistors |
NIIN: 008831548 |
NCB Code: USA (00) |
Manufacturers: Texas Instrument Inc , Micro Uspd Inc |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers TM1-4 1800PORM5PCT, TM1-4 1800OHMSPORM5PCT under NSN 5905-00-883-1548 of Resistor Thermal manufactured by Texas Instrument Inc, Micro Uspd Inc.
Federal Supply Class of NSN 5905-00-883-1548 is FSC 5905 contains part details of Resistors. Quote for your desired part numbers.
Part Number's List for NSN 5905-00-883-1548, 5905008831548
-
Part No Manufacturer Item Name QTY RFQ TM1-4 1800PORM5PCT Texas Instrument Inc resistor thermal Avl RFQ TM1-4 1800OHMSPORM5PCT Micro Uspd Inc resistor thermal Avl RFQ
Characteristics Data of NSN 5905008831548MRC Criteria Characteristic AARG RELIABILITY INDICATOR NOT ESTABLISHED ABDN TERMINAL SURFACE TREATMENT SOLDER ABJT TERMINAL LENGTH 1.375 INCHES MINIMUM AND 1.625 INCHES MAXIMUM ADAQ BODY LENGTH 0.570 INCHES MINIMUM AND 0.600 INCHES MAXIMUM ADAR BODY OUTSIDE DIAMETER 0.185 INCHES MINIMUM AND 0.215 INCHES MAXIMUM AEBT TERMINAL DIAMETER 0.025 INCHES NOMINAL AEHX MAXIMUM POWER DISSIPATION RATING 250.00 MILLIWATTS AEHY AMBIENT TEMP AT FULL RATED POWER 100.0 DEG CELSIUS AEHZ MAXIMUM OPERATING TEMP 150.0 DEG CELSIUS AEJA THERMAL TIME CONSTANT IN SECONDS 60.0 AEJB POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS 250.0 AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER -25.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER -50.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER -65.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER -75.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER 0.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER 100.0 DEG CELSIUS 8TH RESISTANCE-TEMPERATURE POINT AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER 125.0 DEG CELSIUS 9TH RESISTANCE-TEMPERATURE POINT AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER 150.0 DEG CELSIUS 10TH RESISTANCE-TEMPERATURE POINT AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER 50.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER 75.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 1.2 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 1.5 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 2.2 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 2.5 KILOHMS 7TH RESISTANCE-TEMPERATURE POINT AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 3.0 KILOHMS 8TH RESISTANCE-TEMPERATURE POINT AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 3.6 KILOHMS 9TH RESISTANCE-TEMPERATURE POINT AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 4.0 KILOHMS 10TH RESISTANCE-TEMPERATURE POINT AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 783.0 OHMS 1ST RESISTANCE-TEMPERATURE POINT AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 846.0 OHMS 2ND RESISTANCE-TEMPERATURE POINT AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 963.0 OHMS 3RD RESISTANCE-TEMPERATURE POINT AEJF RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT -5.0/+5.0 ALL RESISTANCE-TEMPERATURE POINTS AKNA INCLOSURE TYPE ENCAPSULATED CBME III CUBIC MEASURE 0.022 CUBIC INCHES CQWD III ZERO POWER RESISTANCE 1.800 KILOHMS CRQJ ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP -5.0/+5.0 CTGT REFERENCE TEMP IN DEG CELSIUS 25.0 STYL STYLE DESIGNATOR ROD TTQY TERMINAL TYPE AND QUANTITY 2 WIRE LEAD
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABDN | TERMINAL SURFACE TREATMENT | SOLDER |
ABJT | TERMINAL LENGTH | 1.375 INCHES MINIMUM AND 1.625 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.570 INCHES MINIMUM AND 0.600 INCHES MAXIMUM |
ADAR | BODY OUTSIDE DIAMETER | 0.185 INCHES MINIMUM AND 0.215 INCHES MAXIMUM |
AEBT | TERMINAL DIAMETER | 0.025 INCHES NOMINAL |
AEHX | MAXIMUM POWER DISSIPATION RATING | 250.00 MILLIWATTS |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 100.0 DEG CELSIUS |
AEHZ | MAXIMUM OPERATING TEMP | 150.0 DEG CELSIUS |
AEJA | THERMAL TIME CONSTANT IN SECONDS | 60.0 |
AEJB | POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 250.0 |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -25.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -50.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -65.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -75.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 DEG CELSIUS 8TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 DEG CELSIUS 9TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 150.0 DEG CELSIUS 10TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.2 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.5 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 2.2 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 2.5 KILOHMS 7TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 3.0 KILOHMS 8TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 3.6 KILOHMS 9TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 4.0 KILOHMS 10TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 783.0 OHMS 1ST RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 846.0 OHMS 2ND RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 963.0 OHMS 3RD RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -5.0/+5.0 ALL RESISTANCE-TEMPERATURE POINTS |
AKNA | INCLOSURE TYPE | ENCAPSULATED |
CBME | III CUBIC MEASURE | 0.022 CUBIC INCHES |
CQWD | III ZERO POWER RESISTANCE | 1.800 KILOHMS |
CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -5.0/+5.0 |
CTGT | REFERENCE TEMP IN DEG CELSIUS | 25.0 |
STYL | STYLE DESIGNATOR | ROD |