NSN 5905-00-904-4409 of Resistor Fixed Film - Parts Details
Alternative NSN: 5905009044409 |
Item Name: Resistor Fixed Film |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5905 Resistors |
NIIN: 009044409 |
NCB Code: USA (00) |
Manufacturers: Eca Etablissement Central Des , Trw Inc , North American Philips Corp |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers 5905009044409, CEAT0-1002F, MF5CD1002F, RNC55K1002F under NSN 5905-00-904-4409 of Resistor Fixed Film manufactured by Eca Etablissement Central Des, Trw Inc, North American Philips Corp.
Federal Supply Class of NSN 5905-00-904-4409 is FSC 5905 contains part details of Resistors. Quote for your desired part numbers.
Part Number's List for NSN 5905-00-904-4409, 5905009044409
-
Part No Manufacturer Item Name QTY RFQ 5905009044409 Eca Etablissement Central Des resistor fixed film Avl RFQ CEAT0-1002F Trw Inc resistor fixed film Avl RFQ MF5CD1002F North American Philips Corp resistor fixed film Avl RFQ RNC55K1002F Trw Inc resistor fixed film Avl RFQ
Characteristics Data of NSN 5905009044409MRC Criteria Characteristic AAPE TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS -100.0 TO 100.0 AAPP ELECTRICAL RESISTANCE 10.000 KILOHMS AAPQ RESISTANCE TOLERANCE IN PERCENT -1.000 TO 1.000 AAQF AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER 125.0 AAQG AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER 175.0 AAQH TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS -55.0 TO 175.0 AAQZ INCLOSURE METHOD ENCAPSULATED AARB TERMINAL TYPE WIRE LEAD AARG RELIABILITY INDICATOR NOT ESTABLISHED ABJT TERMINAL LENGTH 1.000 INCHES MINIMUM AND 1.625 INCHES MAXIMUM ABPM BODY DIAMETER 0.078 INCHES MINIMUM AND 0.140 INCHES MAXIMUM ADAQ BODY LENGTH 0.204 INCHES MINIMUM AND 0.281 INCHES MAXIMUM AEFB POWER DISSIPATION RATING IN WATTS 0.100 FREE AIR PKWT UNPACKAGED UNIT WEIGHT 0.35 GRAMS STYL STYLE DESIGNATOR AXIAL TERMINAL EACH END
MRC | Criteria | Characteristic |
---|---|---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -100.0 TO 100.0 |
AAPP | ELECTRICAL RESISTANCE | 10.000 KILOHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -1.000 TO 1.000 |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 125.0 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 175.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 175.0 |
AAQZ | INCLOSURE METHOD | ENCAPSULATED |
AARB | TERMINAL TYPE | WIRE LEAD |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 1.000 INCHES MINIMUM AND 1.625 INCHES MAXIMUM |
ABPM | BODY DIAMETER | 0.078 INCHES MINIMUM AND 0.140 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.204 INCHES MINIMUM AND 0.281 INCHES MAXIMUM |
AEFB | POWER DISSIPATION RATING IN WATTS | 0.100 FREE AIR |
PKWT | UNPACKAGED UNIT WEIGHT | 0.35 GRAMS |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |