NSN 5905-01-018-1694 of Resistor Variable Nonwire Wound - Parts Details
Alternative NSN: 5905010181694 |
Item Name: Resistor Variable Nonwire Wound |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5905 Resistors |
NIIN: 010181694 |
NCB Code: USA (01) |
Manufacturers: Trw Inc |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers 170-10 under NSN 5905-01-018-1694 of Resistor Variable Nonwire Wound manufactured by Trw Inc.
Federal Supply Class of NSN 5905-01-018-1694 is FSC 5905 contains part details of Resistors. Quote for your desired part numbers.
Part Number's List for NSN 5905-01-018-1694, 5905010181694
Characteristics Data of NSN 5905010181694MRC Criteria Characteristic AAPN SECTION QUANTITY 1 AAQL BODY STYLE CYLINDRICAL AARG RELIABILITY INDICATOR NOT ESTABLISHED ABHP III OVERALL LENGTH 0.357 INCHES NOMINAL ABJT TERMINAL LENGTH 0.187 INCHES NOMINAL ABPM BODY DIAMETER 0.250 INCHES NOMINAL ADAQ BODY LENGTH 0.170 INCHES NOMINAL ADAV III OVERALL DIAMETER 0.250 INCHES NOMINAL AEFD ACTUATOR TYPE FLUSH DRIVE WITH SLOT-HOLE AEHT CENTER TO CENTER DISTANCE BETWEEN TERMINALS 0.200 INCHES NOMINAL APXH TERMINAL LOCATION REAR END AXGY MOUNTING METHOD TERMINAL AYQR CENTER TO CENTER DISTANCE BETWEEN TERMINAL ROWS 0.100 INCHES NOMINAL CQCC ELECTRICAL RESISTANCE PER SECTION 10.0 OHMS SINGLE SECTION CQCM CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL 0.100 INCHES NOMINAL CQGN AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER 150.0 SINGLE SECTION CRFJ TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS -100.0 TO 100.0 SINGLE SECTION CRGD POWER DISSIPATION RATING PER SECTION IN WATTS 0.5 FREE AIR SINGLE SECTION CRSS RESISTANCE TOLERANCE PER SECTION IN PERCENT -20.0 TO 20.0 SINGLE SECTION CSDH AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER 85.0 SINGLE SECTION TTQY TERMINAL TYPE AND QUANTITY 3 PIN
MRC | Criteria | Characteristic |
---|---|---|
AAPN | SECTION QUANTITY | 1 |
AAQL | BODY STYLE | CYLINDRICAL |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | III OVERALL LENGTH | 0.357 INCHES NOMINAL |
ABJT | TERMINAL LENGTH | 0.187 INCHES NOMINAL |
ABPM | BODY DIAMETER | 0.250 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.170 INCHES NOMINAL |
ADAV | III OVERALL DIAMETER | 0.250 INCHES NOMINAL |
AEFD | ACTUATOR TYPE | FLUSH DRIVE WITH SLOT-HOLE |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.200 INCHES NOMINAL |
APXH | TERMINAL LOCATION | REAR END |
AXGY | MOUNTING METHOD | TERMINAL |
AYQR | CENTER TO CENTER DISTANCE BETWEEN TERMINAL ROWS | 0.100 INCHES NOMINAL |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 10.0 OHMS SINGLE SECTION |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.100 INCHES NOMINAL |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 150.0 SINGLE SECTION |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -100.0 TO 100.0 SINGLE SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.5 FREE AIR SINGLE SECTION |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -20.0 TO 20.0 SINGLE SECTION |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 85.0 SINGLE SECTION |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |