NSN 5905-01-249-7024 of Resistor Fixed Wire Wound Nonind - Parts Details
Alternative NSN: 5905012497024 |
Item Name: Resistor Fixed Wire Wound Nonind |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5905 Resistors |
NIIN: 012497024 |
NCB Code: USA (01) |
Manufacturers: General Electric Company , Ametek Inc , Ultronix Inc |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers J167P1652A, 6199W14P023, 103A16.5K under NSN 5905-01-249-7024 of Resistor Fixed Wire Wound Nonind manufactured by General Electric Company, Ametek Inc, Ultronix Inc.
Federal Supply Class of NSN 5905-01-249-7024 is FSC 5905 contains part details of Resistors. Quote for your desired part numbers.
Part Number's List for NSN 5905-01-249-7024, 5905012497024
-
Part No Manufacturer Item Name QTY RFQ J167P1652A General Electric Company resistor fixed wire wound nonind Avl RFQ 6199W14P023 Ametek Inc resistor fixed wire wound nonind Avl RFQ 103A16.5K Ultronix Inc resistor fixed wire wound nonind Avl RFQ
Characteristics Data of NSN 5905012497024MRC Criteria Characteristic AAPE TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS -5.0 TO 5.0 AAPP ELECTRICAL RESISTANCE 16.500 KILOHMS AAPQ RESISTANCE TOLERANCE IN PERCENT -1.000 TO 1.000 AAQF AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER 125.0 AAQG AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER 145.0 AAQH TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS -55.0 TO 145.0 AAQZ INCLOSURE METHOD ENCAPSULATED AARB TERMINAL TYPE WIRE LEAD AARG RELIABILITY INDICATOR NOT ESTABLISHED ABJT TERMINAL LENGTH 1.750 INCHES MINIMUM ABPM BODY DIAMETER 0.160 INCHES MAXIMUM ADAQ BODY LENGTH 0.310 INCHES MAXIMUM AEFB POWER DISSIPATION RATING IN WATTS 10.000 FREE AIR CBME CUBIC MEASURE 0.006 CUBIC INCHES PKWT III UNPACKAGED UNIT WEIGHT 1.0 GRAMS STYL STYLE DESIGNATOR AXIAL TERMINAL EACH END ZZZK SPECIFICATION/STANDARD DATA 07482-J167 MANUFACTURERS SOURCE CONTROL
MRC | Criteria | Characteristic |
---|---|---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -5.0 TO 5.0 |
AAPP | ELECTRICAL RESISTANCE | 16.500 KILOHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -1.000 TO 1.000 |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 125.0 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 145.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 145.0 |
AAQZ | INCLOSURE METHOD | ENCAPSULATED |
AARB | TERMINAL TYPE | WIRE LEAD |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 1.750 INCHES MINIMUM |
ABPM | BODY DIAMETER | 0.160 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.310 INCHES MAXIMUM |
AEFB | POWER DISSIPATION RATING IN WATTS | 10.000 FREE AIR |
CBME | CUBIC MEASURE | 0.006 CUBIC INCHES |
PKWT | III UNPACKAGED UNIT WEIGHT | 1.0 GRAMS |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |
ZZZK | SPECIFICATION/STANDARD DATA | 07482-J167 MANUFACTURERS SOURCE CONTROL |