Item Name: Filter Radio Frequency Interfere |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5915 Filters and Networks |
NIIN: 009576807 |
NCB Code: USA (00) |
Manufacturers: L 3 Communications , Sprague Electric Co World Hqs , Cornell Dubilier Electronics |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers 2183370-1, JN10-774, NF20565-1 under NSN 5915-00-957-6807 of Filter Radio Frequency Interfere manufactured by L 3 Communications, Sprague Electric Co World Hqs, Cornell Dubilier Electronics.
Federal Supply Class of NSN 5915-00-957-6807 is FSC 5915 contains part details of Filters and Networks. Quote for your desired part numbers.
Part Number's List for NSN 5915-00-957-6807, 5915009576807
Characteristics Data of NSN 5915009576807MRC Criteria Characteristic ABHP OVERALL LENGTH 5.250 INCHES NOMINAL ADAQ BODY LENGTH 4.970 INCHES MINIMUM AND 5.030 INCHES MAXIMUM ADAR BODY OUTSIDE DIAMETER 1.970 INCHES MINIMUM AND 2.030 INCHES MAXIMUM AECR III VIBRATION RESISTANCE RANGE IN HERTZ +10.0 TO 55.0 AFGA III OPERATING TEMP RANGE -28.0 TO 85.0 DEG CELSIUS AFSV III AVERAGE LIFE RATING IN HOURS 250.0 AHBB POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 400.0 1ST RADIO INTERFERENCE 1ST FUNCTION AHBB POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 400.0 2ND RADIO INTERFERENCE 2ND FUNCTION AHBB POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 400.0 3RD RADIO INTERFERENCE 3RD FUNCTION AHBC OPERATING CURRENT RATING PER FUNCTION IN AMPS 10.0 1ST RADIO INTERFERENCE 1ST FUNCTION AHBC OPERATING CURRENT RATING PER FUNCTION IN AMPS 10.0 2ND RADIO INTERFERENCE 2ND FUNCTION AHBC OPERATING CURRENT RATING PER FUNCTION IN AMPS 10.0 3RD RADIO INTERFERENCE 3RD FUNCTION AHBE MAXIMUM VOLTAGE DROP PER FUNCTION 500.0 MILLIVOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION AHBE MAXIMUM VOLTAGE DROP PER FUNCTION 500.0 MILLIVOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION AHBE MAXIMUM VOLTAGE DROP PER FUNCTION 500.0 MILLIVOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION AKNA INCLOSURE TYPE HERMETICALLY SEALED AXHR MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED HOLE CQDW FUNCTIONAL TERMINAL TYPE AND QUANTITY 3 THREADED STUD INPUT 1ST FUNCTION CQDW FUNCTIONAL TERMINAL TYPE AND QUANTITY 3 THREADED STUD OUTPUT 2ND FUNCTION CQGC OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION CQGC OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION CQGC OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 115.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION CRDC III MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE 500.0 VOLTS AT SEA LEVEL STYL STYLE DESIGNATOR ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 5.250 INCHES NOMINAL |
ADAQ | BODY LENGTH | 4.970 INCHES MINIMUM AND 5.030 INCHES MAXIMUM |
ADAR | BODY OUTSIDE DIAMETER | 1.970 INCHES MINIMUM AND 2.030 INCHES MAXIMUM |
AECR | III VIBRATION RESISTANCE RANGE IN HERTZ | +10.0 TO 55.0 |
AFGA | III OPERATING TEMP RANGE | -28.0 TO 85.0 DEG CELSIUS |
AFSV | III AVERAGE LIFE RATING IN HOURS | 250.0 |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 500.0 MILLIVOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 500.0 MILLIVOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 500.0 MILLIVOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED HOLE |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 THREADED STUD INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 THREADED STUD OUTPUT 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CRDC | III MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 500.0 VOLTS AT SEA LEVEL |
STYL | STYLE DESIGNATOR | ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES |