NSN 5925-00-465-9917 of Circuit Breaker - Parts Details
Alternative NSN: 5925004659917 |
Item Name: Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 004659917 |
NCB Code: USA (00) |
Manufacturers: Sensata Technologies Inc , Raytheon Aircraft |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers AP333-285-2A, AP333-285-2, 168894-2 under NSN 5925-00-465-9917 of Circuit Breaker manufactured by Sensata Technologies Inc, Raytheon Aircraft.
Federal Supply Class of NSN 5925-00-465-9917 is FSC 5925 contains part details of Circuit Breakers. Quote for your desired part numbers.
Part Number's List for NSN 5925-00-465-9917, 5925004659917
-
Part No Manufacturer Item Name QTY RFQ AP333-285-2A Sensata Technologies Inc circuit breaker Avl RFQ AP333-285-2 Sensata Technologies Inc circuit breaker Avl RFQ 168894-2 Raytheon Aircraft circuit breaker Avl RFQ
Characteristics Data of NSN 5925004659917MRC Criteria Characteristic AAQL BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE ABXD BUSHING LENGTH 0.380 INCHES MAXIMUM ADAQ BODY LENGTH 1.500 INCHES MAXIMUM ADAT BODY WIDTH 1.875 INCHES MAXIMUM ADTV CASE MATERIAL METAL AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.875 INCHES NOMINAL AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.625 INCHES NOMINAL AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 1.780 INCHES MAXIMUM AKPX POLE QUANTITY 3 APNQ ARC QUENCHING METHOD MAGNETIC BLOWOUT AXHR MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE CMLP THREAD QUANTITY PER INCH 32 CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 1.0 AMPERES DC FIRST LOCATION CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 1.0 AMPERES DC THIRD LOCATION CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 3.5 AMPERES DC SECOND LOCATION CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 31.0 DC ALL LOCATIONS CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 DC ALL LOCATIONS CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS CPRJ TRIP RELEASE METHOD MAGNETIC-HYDRAULIC ALL LOCATIONS CPRL TRIP RELEASE CHARACTERISTIC INSTANTANEOUS ALL LOCATIONS CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 115.0 ALL LOCATIONS CPRQ RESET METHOD MANUAL CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE CPRW ACTUATOR FUNCTION TRIP-RESET CPRX ACTUATOR POSITION DESIGNATION AT POLE TWO CPSM INTERNAL TRIP RELEASE CONFIGURATION SHUNT TRIP ALL LOCATIONS CQJX NOMINAL THREAD SIZE 0.375 INCHES CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED HERMETICALLY SEALED PKWT UNPACKAGED UNIT WEIGHT 14.000 OUNCES THSD THREAD SERIES DESIGNATOR UNEF TTQY TERMINAL TYPE AND QUANTITY 9 WIRE HOOK
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
ABXD | BUSHING LENGTH | 0.380 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 1.500 INCHES MAXIMUM |
ADAT | BODY WIDTH | 1.875 INCHES MAXIMUM |
ADTV | CASE MATERIAL | METAL |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.875 INCHES NOMINAL |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.625 INCHES NOMINAL |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.780 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 3 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 1.0 AMPERES DC FIRST LOCATION |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 1.0 AMPERES DC THIRD LOCATION |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 3.5 AMPERES DC SECOND LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 31.0 DC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 DC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 115.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SHUNT TRIP ALL LOCATIONS |
CQJX | NOMINAL THREAD SIZE | 0.375 INCHES |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | HERMETICALLY SEALED |
PKWT | UNPACKAGED UNIT WEIGHT | 14.000 OUNCES |
THSD | THREAD SERIES DESIGNATOR | UNEF |
TTQY | TERMINAL TYPE AND QUANTITY | 9 WIRE HOOK |