NSN 5925-00-476-4551 of Circuit Breaker - Parts Details
Alternative NSN: 5925004764551 |
Item Name: Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 004764551 |
NCB Code: USA (00) |
Manufacturers: Sensata Technologies Inc |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers AP-112-1-42-502 under NSN 5925-00-476-4551 of Circuit Breaker manufactured by Sensata Technologies Inc.
Federal Supply Class of NSN 5925-00-476-4551 is FSC 5925 contains part details of Circuit Breakers. Quote for your desired part numbers.
Part Number's List for NSN 5925-00-476-4551, 5925004764551
-
Part No Manufacturer Item Name QTY RFQ AP-112-1-42-502 Sensata Technologies Inc circuit breaker Avl RFQ
Characteristics Data of NSN 5925004764551MRC Criteria Characteristic AAQL BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE ABXD BUSHING LENGTH 0.380 INCHES MAXIMUM ADAQ BODY LENGTH 1.500 INCHES MAXIMUM ADAT BODY WIDTH 1.875 INCHES MAXIMUM ADTV CASE MATERIAL METAL AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.844 INCHES MINIMUM AND 0.906 INCHES MAXIMUM AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.594 INCHES MINIMUM AND 0.656 INCHES MAXIMUM AFJN FRAGILITY FACTOR MODERATELY RUGGED AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 1.780 INCHES MAXIMUM AKPX POLE QUANTITY 3 APNQ ARC QUENCHING METHOD MAGNETIC BLOWOUT AXHR MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING W/PANEL SEAL BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE BBRJ SPECIAL HANDLING FEATURE MAGNETIC CMLP THREAD QUANTITY PER INCH 32 CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 5.0 AMPERES AC ALL LOCATIONS CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 240.0 AC ALL LOCATIONS CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC ALL LOCATIONS CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS CPRJ TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 150.0 ALL LOCATIONS CPRQ RESET METHOD MANUAL CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE CPRW ACTUATOR FUNCTION TRIP-RESET CPRX ACTUATOR POSITION DESIGNATION AT POLE TWO CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS CQJX NOMINAL THREAD SIZE 0.375 INCHES CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.900 MINIMUM AT 200 PCT ALL LOCATIONS AND 4.000 MAXIMUM AT 200 PCT ALL LOCATIONS CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED HERMETICALLY SEALED AND SHOCK RESISTANT AND VIBRATION RESISTANT FREQ FREQUENCY IN HERTZ 400.0 ALL LOCATIONS THSD THREAD SERIES DESIGNATOR UNEF TTQY TERMINAL TYPE AND QUANTITY 6 WIRE HOOK
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
ABXD | BUSHING LENGTH | 0.380 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 1.500 INCHES MAXIMUM |
ADAT | BODY WIDTH | 1.875 INCHES MAXIMUM |
ADTV | CASE MATERIAL | METAL |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.844 INCHES MINIMUM AND 0.906 INCHES MAXIMUM |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.594 INCHES MINIMUM AND 0.656 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.780 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 3 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING W/PANEL SEAL |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 5.0 AMPERES AC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 150.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CQJX | NOMINAL THREAD SIZE | 0.375 INCHES |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.900 MINIMUM AT 200 PCT ALL LOCATIONS AND 4.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | HERMETICALLY SEALED AND SHOCK RESISTANT AND VIBRATION RESISTANT |
FREQ | FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS |
THSD | THREAD SERIES DESIGNATOR | UNEF |
TTQY | TERMINAL TYPE AND QUANTITY | 6 WIRE HOOK |