NSN 5925-00-689-4646 of Circuit Breaker - Parts Details
Alternative NSN: 5925006894646 |
Item Name: Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 006894646 |
NCB Code: USA (00) |
Manufacturers: Sensata Technologies Inc , Terex Usa Llc Dba Cedarapids |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers CDM-15-I, 46165-001-41 under NSN 5925-00-689-4646 of Circuit Breaker manufactured by Sensata Technologies Inc, Terex Usa Llc Dba Cedarapids.
Federal Supply Class of NSN 5925-00-689-4646 is FSC 5925 contains part details of Circuit Breakers. Quote for your desired part numbers.
Part Number's List for NSN 5925-00-689-4646, 5925006894646
-
Part No Manufacturer Item Name QTY RFQ CDM-15-I Sensata Technologies Inc circuit breaker Avl RFQ 46165-001-41 Terex Usa Llc Dba Cedarapids circuit breaker Avl RFQ
Characteristics Data of NSN 5925006894646MRC Criteria Characteristic AAQL BODY STYLE SINGLE POLE TYPE ABHP OVERALL LENGTH 2.000 INCHES MAXIMUM ADAT BODY WIDTH 1.250 INCHES NOMINAL ADTV CASE MATERIAL PLASTIC AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.906 INCHES NOMINAL AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 1.574 INCHES NOMINAL AKPX POLE QUANTITY 1 AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED HOLE BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE CMLP THREAD QUANTITY PER INCH 32 CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 15.0 AMPERES DC SINGLE LOCATION CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 30.0 DC SINGLE LOCATION CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION CPRJ TRIP RELEASE METHOD THERMAL SINGLE LOCATION CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 100.0 SINGLE LOCATION CPRQ RESET METHOD MANUAL CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 PUSH BUTTON CPRW ACTUATOR FUNCTION TRIP-RESET CPRX ACTUATOR POSITION DESIGNATION AT POLE ONE CQJX NOMINAL THREAD SIZE 0.164 INCHES CRCF TRIP RELEASE AMBIENT TEMP RATING 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION THSD THREAD SERIES DESIGNATOR UNC TTQY TERMINAL TYPE AND QUANTITY 2 SCREW AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 1.266 INCHES MAXIMUM CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 600.0 DC SINGLE LOCATION CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SINGLE LOCATION CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 5.500 MINIMUM AT 200 PCT SINGLE LOCATION AND 55.000 MAXIMUM AT 200 PCT SINGLE LOCATION CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED WEATHERPROOF
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | SINGLE POLE TYPE |
ABHP | OVERALL LENGTH | 2.000 INCHES MAXIMUM |
ADAT | BODY WIDTH | 1.250 INCHES NOMINAL |
ADTV | CASE MATERIAL | PLASTIC |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.906 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.574 INCHES NOMINAL |
AKPX | POLE QUANTITY | 1 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 15.0 AMPERES DC SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 30.0 DC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | THERMAL SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 100.0 SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH BUTTON |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
THSD | THREAD SERIES DESIGNATOR | UNC |
TTQY | TERMINAL TYPE AND QUANTITY | 2 SCREW |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.266 INCHES MAXIMUM |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 600.0 DC SINGLE LOCATION |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 5.500 MINIMUM AT 200 PCT SINGLE LOCATION AND 55.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | WEATHERPROOF |