NSN 5925-00-703-3589 of Circuit Breaker - Parts Details
Alternative NSN: 5925007033589 |
Item Name: Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 007033589 |
NCB Code: USA (00) |
Manufacturers: Dla Land And Maritime , Wood Electric Operations Potter And Brumfield , Navair Ltd |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers DMS84021B, 1825, 1127283, 102-225-101 under NSN 5925-00-703-3589 of Circuit Breaker manufactured by Dla Land And Maritime, Wood Electric Operations Potter And Brumfield, Navair Ltd.
Federal Supply Class of NSN 5925-00-703-3589 is FSC 5925 contains part details of Circuit Breakers. Quote for your desired part numbers.
Part Number's List for NSN 5925-00-703-3589, 5925007033589
Characteristics Data of NSN 5925007033589MRC Criteria Characteristic ADTV CASE MATERIAL PLASTIC AKPX POLE QUANTITY 1 CMLP THREAD QUANTITY PER INCH 32 CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 25.0 AMPERES AC SINGLE LOCATION AND 25.0 AMPERES DC SINGLE LOCATION CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC SINGLE LOCATION AND 32.0 DC SINGLE LOCATION CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 3000.0 AC SINGLE LOCATION AND 5000.0 DC SINGLE LOCATION CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION CPRJ TRIP RELEASE METHOD THERMAL SINGLE LOCATION CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 138.0 SINGLE LOCATION CPRQ RESET METHOD MANUAL CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE CPRW ACTUATOR FUNCTION TRIP-RESET CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 20.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 80.000 MAXIMUM AT 200 PCT SINGLE LOCATION CRCF TRIP RELEASE AMBIENT TEMP RATING 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION THSD THREAD SERIES DESIGNATOR UNC TTQY TERMINAL TYPE AND QUANTITY 2 SCREW AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED HOLE CPSM INTERNAL TRIP RELEASE CONFIGURATION RELAY TRIP SINGLE LOCATION CQJX NOMINAL THREAD SIZE 0.138 INCHES
MRC | Criteria | Characteristic |
---|---|---|
ADTV | CASE MATERIAL | PLASTIC |
AKPX | POLE QUANTITY | 1 |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 25.0 AMPERES AC SINGLE LOCATION AND 25.0 AMPERES DC SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC SINGLE LOCATION AND 32.0 DC SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 3000.0 AC SINGLE LOCATION AND 5000.0 DC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | THERMAL SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 138.0 SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 20.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 80.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
THSD | THREAD SERIES DESIGNATOR | UNC |
TTQY | TERMINAL TYPE AND QUANTITY | 2 SCREW |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | RELAY TRIP SINGLE LOCATION |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |