NSN 5925-00-728-1289 of Circuit Breaker - Parts Details
Alternative NSN: 5925007281289 |
Item Name: Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 007281289 |
NCB Code: USA (00) |
Manufacturers: Grainger Div Of W W Grainger Inc , American Development Corp , Schneider Canada Inc , Schneider Electric Usa Inc , Square D Company |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers 1H824, F151311-1, Q0B120, Q0B120H, QOB120 under NSN 5925-00-728-1289 of Circuit Breaker manufactured by Grainger Div Of W W Grainger Inc, American Development Corp, Schneider Canada Inc, Schneider Electric Usa Inc, Square D Company.
Federal Supply Class of NSN 5925-00-728-1289 is FSC 5925 contains part details of Circuit Breakers. Quote for your desired part numbers.
Part Number's List for NSN 5925-00-728-1289, 5925007281289
-
Part No Manufacturer Item Name QTY RFQ 1H824 Grainger Div Of W W Grainger Inc circuit breaker Avl RFQ F151311-1 American Development Corp circuit breaker Avl RFQ Q0B120 Schneider Canada Inc circuit breaker Avl RFQ Q0B120 Schneider Electric Usa Inc circuit breaker Avl RFQ Q0B120H Square D Company circuit breaker Avl RFQ QOB120 Schneider Electric Usa Inc circuit breaker Avl RFQ
Characteristics Data of NSN 5925007281289MRC Criteria Characteristic AAQL BODY STYLE SINGLE POLE TYPE ADAT BODY WIDTH 0.730 INCHES NOMINAL ADAU BODY HEIGHT 3.180 INCHES NOMINAL ADTV CASE MATERIAL PLASTIC AJEC BOSS HEIGHT 0.160 INCHES NOMINAL AKPX POLE QUANTITY 1 AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 TERMINAL BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 20.0 AMPERES AC SINGLE LOCATION CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 120.0 AC SINGLE LOCATION CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 5000.0 AC SINGLE LOCATION CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION CPRJ TRIP RELEASE METHOD THERMAL-MAGNETIC SINGLE LOCATION CPRL TRIP RELEASE CHARACTERISTIC INSTANTANEOUS SINGLE LOCATION AND TIME DELAY SINGLE LOCATION CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 SINGLE LOCATION CPRQ RESET METHOD MANUAL CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE CPRX ACTUATOR POSITION DESIGNATION AT POLE ONE CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 15.000 NOMINAL AT 200 PCT SINGLE LOCATION AND 5.000 NOMINAL AT 300 PCT SINGLE LOCATION CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT FREQ FREQUENCY IN HERTZ 60.0 SINGLE LOCATION TTQY TERMINAL TYPE AND QUANTITY 1 CLIP AND 1 COMPRESSION ADAQ BODY LENGTH 3.000 INCHES NOMINAL CPRW ACTUATOR FUNCTION TRIP-RESET CRCF TRIP RELEASE AMBIENT TEMP RATING 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | SINGLE POLE TYPE |
ADAT | BODY WIDTH | 0.730 INCHES NOMINAL |
ADAU | BODY HEIGHT | 3.180 INCHES NOMINAL |
ADTV | CASE MATERIAL | PLASTIC |
AJEC | BOSS HEIGHT | 0.160 INCHES NOMINAL |
AKPX | POLE QUANTITY | 1 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 TERMINAL |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 20.0 AMPERES AC SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 120.0 AC SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS SINGLE LOCATION AND TIME DELAY SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 15.000 NOMINAL AT 200 PCT SINGLE LOCATION AND 5.000 NOMINAL AT 300 PCT SINGLE LOCATION |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT |
FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE LOCATION |
TTQY | TERMINAL TYPE AND QUANTITY | 1 CLIP AND 1 COMPRESSION |
ADAQ | BODY LENGTH | 3.000 INCHES NOMINAL |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |