NSN 5925-00-752-6907 of Circuit Breaker - Parts Details
Alternative NSN: 5925007526907 |
Item Name: Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 007526907 |
NCB Code: USA (00) |
Manufacturers: Sensata Technologies Inc |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers C9115-1-20 under NSN 5925-00-752-6907 of Circuit Breaker manufactured by Sensata Technologies Inc.
Federal Supply Class of NSN 5925-00-752-6907 is FSC 5925 contains part details of Circuit Breakers. Quote for your desired part numbers.
Part Number's List for NSN 5925-00-752-6907, 5925007526907
-
Part No Manufacturer Item Name QTY RFQ C9115-1-20 Sensata Technologies Inc circuit breaker Avl RFQ
Characteristics Data of NSN 5925007526907MRC Criteria Characteristic AAQL BODY STYLE RECTANGULAR DIMENSIONAL ENVELOPE ABHP OVERALL LENGTH 2.000 INCHES NOMINAL ABMK OVERALL WIDTH 1.813 INCHES NOMINAL AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.174 INCHES NOMINAL AKPX POLE QUANTITY 1 AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 UNTHREADED HOLE CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 20.0 AMPERES AC SINGLE LOCATION AND 20.0 AMPERES DC SINGLE LOCATION CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 900.0 AC SINGLE LOCATION AND 900.0 DC SINGLE LOCATION CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION CPRJ TRIP RELEASE METHOD THERMAL SINGLE LOCATION CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 115.0 SINGLE LOCATION CPRQ RESET METHOD AUTOMATIC CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SINGLE LOCATION CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 3600.000 NOMINAL AT 125 PCT SINGLE LOCATION AND 300.000 NOMINAL AT 200 PCT SINGLE LOCATION CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED WATERTIGHT CRCF TRIP RELEASE AMBIENT TEMP RATING 25.0 DEG CELSIUS MAXIMUM SINGLE LOCATION ABKW OVERALL HEIGHT 1.672 INCHES NOMINAL ADTV CASE MATERIAL PLASTIC CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 30.0 AC SINGLE LOCATION AND 30.0 DC SINGLE LOCATION FREQ FREQUENCY IN HERTZ 60.0 SINGLE LOCATION TEST TEST DATA DOCUMENT 81349-MIL-C-13516 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTI TTQY TERMINAL TYPE AND QUANTITY 2 QUICK DISCONNECT, MALE
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | RECTANGULAR DIMENSIONAL ENVELOPE |
ABHP | OVERALL LENGTH | 2.000 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.813 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.174 INCHES NOMINAL |
AKPX | POLE QUANTITY | 1 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 20.0 AMPERES AC SINGLE LOCATION AND 20.0 AMPERES DC SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 900.0 AC SINGLE LOCATION AND 900.0 DC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | THERMAL SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 115.0 SINGLE LOCATION |
CPRQ | RESET METHOD | AUTOMATIC |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 3600.000 NOMINAL AT 125 PCT SINGLE LOCATION AND 300.000 NOMINAL AT 200 PCT SINGLE LOCATION |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | WATERTIGHT |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS MAXIMUM SINGLE LOCATION |
ABKW | OVERALL HEIGHT | 1.672 INCHES NOMINAL |
ADTV | CASE MATERIAL | PLASTIC |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 30.0 AC SINGLE LOCATION AND 30.0 DC SINGLE LOCATION |
FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE LOCATION |
TEST | TEST DATA DOCUMENT | 81349-MIL-C-13516 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTI |
TTQY | TERMINAL TYPE AND QUANTITY | 2 QUICK DISCONNECT, MALE |