NSN 5925-00-855-3987 of Circuit Breaker - Parts Details
Alternative NSN: 5925008553987 |
Item Name: Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 008553987 |
NCB Code: USA (00) |
Manufacturers: Tyco Electronics , Wood Electric Operations Potter And Brumfield |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers W31X2A1G-20, W31-X2M1G-20, 112-220-101 under NSN 5925-00-855-3987 of Circuit Breaker manufactured by Tyco Electronics, Wood Electric Operations Potter And Brumfield.
Federal Supply Class of NSN 5925-00-855-3987 is FSC 5925 contains part details of Circuit Breakers. Quote for your desired part numbers.
Part Number's List for NSN 5925-00-855-3987, 5925008553987
-
Part No Manufacturer Item Name QTY RFQ W31X2A1G-20 Tyco Electronics circuit breaker Avl RFQ W31-X2M1G-20 Tyco Electronics circuit breaker Avl RFQ 112-220-101 Wood Electric Operations Potter And Brumfield circuit breaker Avl RFQ 112-220-101 Tyco Electronics circuit breaker Avl RFQ
Characteristics Data of NSN 5925008553987MRC Criteria Characteristic AAQL BODY STYLE SINGLE POLE TYPE ABXD BUSHING LENGTH 0.625 INCHES NOMINAL ADAQ BODY LENGTH 1.375 INCHES NOMINAL ADAT BODY WIDTH 0.690 INCHES NOMINAL ADTV CASE MATERIAL PLASTIC AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.020 INCHES NOMINAL AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 2.035 INCHES NOMINAL AKPX POLE QUANTITY 1 AXHR MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE CMLP THREAD QUANTITY PER INCH 32 CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 20.0 AMPERES AC SINGLE LOCATION AND 20.0 AMPERES DC SINGLE LOCATION CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC SINGLE LOCATION AND 50.0 DC SINGLE LOCATION CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC SINGLE LOCATION AND 2500.0 DC SINGLE LOCATION CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 135.0 SINGLE LOCATION CPRQ RESET METHOD MANUAL CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE CPRW ACTUATOR FUNCTION TRIP-RESET CPRX ACTUATOR POSITION DESIGNATION AT POLE ONE CQJX NOMINAL THREAD SIZE 0.469 INCHES CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED HUMIDITY PROOF AND SALT SPRAY PROOF AND SHOCKPROOF AND VIBRATIONPROOF PKWT UNPACKAGED UNIT WEIGHT 0.125 POUNDS TTQY TERMINAL TYPE AND QUANTITY 2 TAB W/SCREW AFJN FRAGILITY FACTOR MODERATELY RUGGED APNQ ARC QUENCHING METHOD AIR CPRJ TRIP RELEASE METHOD THERMAL SINGLE LOCATION CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SINGLE LOCATION CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 6.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION CRCF TRIP RELEASE AMBIENT TEMP RATING 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION FREQ FREQUENCY IN HERTZ 400.0 SINGLE LOCATION THSD THREAD SERIES DESIGNATOR UNS
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | SINGLE POLE TYPE |
ABXD | BUSHING LENGTH | 0.625 INCHES NOMINAL |
ADAQ | BODY LENGTH | 1.375 INCHES NOMINAL |
ADAT | BODY WIDTH | 0.690 INCHES NOMINAL |
ADTV | CASE MATERIAL | PLASTIC |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.020 INCHES NOMINAL |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.035 INCHES NOMINAL |
AKPX | POLE QUANTITY | 1 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 20.0 AMPERES AC SINGLE LOCATION AND 20.0 AMPERES DC SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC SINGLE LOCATION AND 50.0 DC SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC SINGLE LOCATION AND 2500.0 DC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 135.0 SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
CQJX | NOMINAL THREAD SIZE | 0.469 INCHES |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | HUMIDITY PROOF AND SALT SPRAY PROOF AND SHOCKPROOF AND VIBRATIONPROOF |
PKWT | UNPACKAGED UNIT WEIGHT | 0.125 POUNDS |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB W/SCREW |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
APNQ | ARC QUENCHING METHOD | AIR |
CPRJ | TRIP RELEASE METHOD | THERMAL SINGLE LOCATION |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 6.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
FREQ | FREQUENCY IN HERTZ | 400.0 SINGLE LOCATION |
THSD | THREAD SERIES DESIGNATOR | UNS |