NSN 5925-01-056-7608 of Circuit Breaker - Parts Details
Alternative NSN: 5925010567608 |
Item Name: Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 010567608 |
NCB Code: USA (01) |
Manufacturers: Eaton Corp , Ellis And Watts International Llc |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers AM3-Z633-1, AM3-A3A3A16, 20L4-103 under NSN 5925-01-056-7608 of Circuit Breaker manufactured by Eaton Corp, Ellis And Watts International Llc.
Federal Supply Class of NSN 5925-01-056-7608 is FSC 5925 contains part details of Circuit Breakers. Quote for your desired part numbers.
Part Number's List for NSN 5925-01-056-7608, 5925010567608
-
Part No Manufacturer Item Name QTY RFQ AM3-Z633-1 Eaton Corp circuit breaker Avl RFQ AM3-A3A3A16 Eaton Corp circuit breaker Avl RFQ 20L4-103 Ellis And Watts International Llc circuit breaker Avl RFQ
Characteristics Data of NSN 5925010567608MRC Criteria Characteristic AAQL BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE ADAQ BODY LENGTH 2.437 INCHES MINIMUM AND 2.563 INCHES MAXIMUM ADAT BODY WIDTH 2.187 INCHES MINIMUM AND 2.313 INCHES MAXIMUM ADTV CASE MATERIAL PLASTIC AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 2.000 INCHES MINIMUM AND 2.127 INCHES MAXIMUM AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.687 INCHES MINIMUM AND 0.813 INCHES MAXIMUM AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.000 INCHES MINIMUM AND 2.127 INCHES MAXIMUM AEHA DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.687 INCHES MINIMUM AND 0.813 INCHES MAXIMUM AFJN FRAGILITY FACTOR MODERATELY RUGGED AJEC BOSS HEIGHT 0.062 INCHES MINIMUM AND 0.188 INCHES MAXIMUM AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 2.375 INCHES MINIMUM AND 2.501 INCHES MAXIMUM AKPX POLE QUANTITY 3 APNQ ARC QUENCHING METHOD MAGNETIC BLOWOUT AXHR MOUNTING FACILITY TYPE AND QUANTITY 6 THREADED HOLE BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE CMLP THREAD QUANTITY PER INCH 32 CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 40.0 AMPERES AC ALL LOCATIONS CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC ALL LOCATIONS CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC ALL LOCATIONS CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS CPRJ TRIP RELEASE METHOD MAGNETIC-HYDRAULIC ALL LOCATIONS CPRK AUXILIARY TRIP COIL VOLTAGE TYPE AND RATING IN VOLTS 150.0 AC NOMINAL THIRD LOCATION CPRL TRIP RELEASE CHARACTERISTIC INSTANTANEOUS THIRD LOCATION AND TIME DELAY THIRD LOCATION CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY FIRST LOCATION CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY SECOND LOCATION CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 ALL LOCATIONS CPRQ RESET METHOD MANUAL CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE CPRT MANUAL ACTUATOR TYPE AND QUANTITY 3 TOGGLE CPRW ACTUATOR FUNCTION TRIP-RESET CPRX ACTUATOR POSITION DESIGNATION AT EACH POLE CPRY EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, AND THREE LINKED CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP FIRST LOCATION CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SECOND LOCATION CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES/RELAY TRIP THIRD LOCATION CQJX NOMINAL THREAD SIZE 0.138 INCHES CQQC TRIP RELEASE DUTY CYCLE CONTINUOUS THIRD LOCATION CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 2.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED GENERAL PURPOSE FREQ FREQUENCY IN HERTZ 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS PKWT UNPACKAGED UNIT WEIGHT 10.000 OUNCES THSD THREAD SERIES DESIGNATOR UNC TTQY TERMINAL TYPE AND QUANTITY 8 THREADED STUD
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
ADAQ | BODY LENGTH | 2.437 INCHES MINIMUM AND 2.563 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.187 INCHES MINIMUM AND 2.313 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 2.000 INCHES MINIMUM AND 2.127 INCHES MAXIMUM |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.687 INCHES MINIMUM AND 0.813 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.000 INCHES MINIMUM AND 2.127 INCHES MAXIMUM |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.687 INCHES MINIMUM AND 0.813 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJEC | BOSS HEIGHT | 0.062 INCHES MINIMUM AND 0.188 INCHES MAXIMUM |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.375 INCHES MINIMUM AND 2.501 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 3 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 THREADED HOLE |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 40.0 AMPERES AC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS |
CPRK | AUXILIARY TRIP COIL VOLTAGE TYPE AND RATING IN VOLTS | 150.0 AC NOMINAL THIRD LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS THIRD LOCATION AND TIME DELAY THIRD LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY FIRST LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SECOND LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 3 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE, TWO, AND THREE LINKED |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP FIRST LOCATION |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SECOND LOCATION |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES/RELAY TRIP THIRD LOCATION |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
CQQC | TRIP RELEASE DUTY CYCLE | CONTINUOUS THIRD LOCATION |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | GENERAL PURPOSE |
FREQ | FREQUENCY IN HERTZ | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
PKWT | UNPACKAGED UNIT WEIGHT | 10.000 OUNCES |
THSD | THREAD SERIES DESIGNATOR | UNC |
TTQY | TERMINAL TYPE AND QUANTITY | 8 THREADED STUD |