NSN 5925-01-067-4899 of Circuit Breaker - Parts Details
Alternative NSN: 5925010674899 |
Item Name: Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 010674899 |
NCB Code: USA (01) |
Manufacturers: Tyco Electronics , Wood Electric Operations Potter And Brumfield |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers W68X2Q3-2-5 under NSN 5925-01-067-4899 of Circuit Breaker manufactured by Tyco Electronics, Wood Electric Operations Potter And Brumfield.
Federal Supply Class of NSN 5925-01-067-4899 is FSC 5925 contains part details of Circuit Breakers. Quote for your desired part numbers.
Part Number's List for NSN 5925-01-067-4899, 5925010674899
-
Part No Manufacturer Item Name QTY RFQ W68X2Q3-2-5 Tyco Electronics circuit breaker Avl RFQ W68X2Q3-2-5 Wood Electric Operations Potter And Brumfield circuit breaker Avl RFQ
Characteristics Data of NSN 5925010674899MRC Criteria Characteristic CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS THSD THREAD SERIES DESIGNATOR UNC CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 ALL LOCATIONS ADAQ BODY LENGTH 2.000 INCHES NOMINAL APNQ III ARC QUENCHING METHOD MAGNETIC BLOWOUT CQJX NOMINAL THREAD SIZE 0.138 INCHES CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT AND MOISTURE RESISTANT AKPX POLE QUANTITY 2 PKWT III UNPACKAGED UNIT WEIGHT 4.500 OUNCES CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 240.0 AC ALL LOCATIONS CMLP THREAD QUANTITY PER INCH 32 AEHA DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.750 INCHES NOMINAL CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC ALL LOCATIONS ADAT BODY WIDTH 1.500 INCHES NOMINAL CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 5.0 AMPERES AC ALL LOCATIONS FREQ FREQUENCY IN HERTZ 400.0 ALL LOCATIONS AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.560 INCHES NOMINAL CPRQ RESET METHOD MANUAL AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.750 INCHES NOMINAL AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 THREADED HOLE BBRG III STORAGE TYPE GENERAL PURPOSE WAREHOUSE CPRT MANUAL ACTUATOR TYPE AND QUANTITY 2 TOGGLE TTQY TERMINAL TYPE AND QUANTITY 4 QUICK DISCONNECT, MALE AAQL BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS CPRW ACTUATOR FUNCTION TRIP-RESET CPRX ACTUATOR POSITION DESIGNATION AT EACH POLE CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 2.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS AJEC BOSS HEIGHT 0.130 INCHES NOMINAL CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS ADTV CASE MATERIAL PLASTIC AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 1.880 INCHES NOMINAL CPRJ TRIP RELEASE METHOD MAGNETIC-HYDRAULIC ALL LOCATIONS AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 1.660 INCHES NOMINAL
MRC | Criteria | Characteristic |
---|---|---|
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
THSD | THREAD SERIES DESIGNATOR | UNC |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
ADAQ | BODY LENGTH | 2.000 INCHES NOMINAL |
APNQ | III ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND MOISTURE RESISTANT |
AKPX | POLE QUANTITY | 2 |
PKWT | III UNPACKAGED UNIT WEIGHT | 4.500 OUNCES |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC ALL LOCATIONS |
CMLP | THREAD QUANTITY PER INCH | 32 |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.750 INCHES NOMINAL |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC ALL LOCATIONS |
ADAT | BODY WIDTH | 1.500 INCHES NOMINAL |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 5.0 AMPERES AC ALL LOCATIONS |
FREQ | FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.560 INCHES NOMINAL |
CPRQ | RESET METHOD | MANUAL |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.750 INCHES NOMINAL |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
BBRG | III STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 2 TOGGLE |
TTQY | TERMINAL TYPE AND QUANTITY | 4 QUICK DISCONNECT, MALE |
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
AJEC | BOSS HEIGHT | 0.130 INCHES NOMINAL |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
ADTV | CASE MATERIAL | PLASTIC |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.880 INCHES NOMINAL |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.660 INCHES NOMINAL |