NSN 5925-01-173-1763 of Circuit Breaker - Parts Details
Alternative NSN: 5925011731763 |
Item Name: Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 011731763 |
NCB Code: USA (01) |
Manufacturers: Inspektorat Wsparcia Sil Zbrojnych , Agustawestland International Lim , Sensata Technologies Inc , Rockwell Collins Inc |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers 5925PL0694564, 3TC14-35, 214-0044-050 under NSN 5925-01-173-1763 of Circuit Breaker manufactured by Inspektorat Wsparcia Sil Zbrojnych, Agustawestland International Lim, Sensata Technologies Inc, Rockwell Collins Inc.
Federal Supply Class of NSN 5925-01-173-1763 is FSC 5925 contains part details of Circuit Breakers. Quote for your desired part numbers.
Part Number's List for NSN 5925-01-173-1763, 5925011731763
-
Part No Manufacturer Item Name QTY RFQ 5925PL0694564 Inspektorat Wsparcia Sil Zbrojnych circuit breaker Avl RFQ 3TC14-35 Agustawestland International Lim circuit breaker Avl RFQ 3TC14-35 Sensata Technologies Inc circuit breaker Avl RFQ 214-0044-050 Rockwell Collins Inc circuit breaker Avl RFQ
Characteristics Data of NSN 5925011731763MRC Criteria Characteristic AAJE THREAD PITCH DIAMETERS +0.444/+0.447 INCHES AAQL ABXD BUSHING LENGTH 0.250 INCHES NOMINAL ADAQ BODY LENGTH 1.100 INCHES MAXIMUM ADAT BODY WIDTH 0.781 INCHES MAXIMUM ADTV CASE MATERIAL PLASTIC AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.704 INCHES NOMINAL AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 1.218 INCHES NOMINAL AKPX POLE QUANTITY 1 AXHR MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING CMLP THREAD QUANTITY PER INCH 32 CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 35.0 AMPERES AC SINGLE LOCATION AND 35.0 AMPERES DC SINGLE LOCATION CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 120.0 AC SINGLE LOCATION AND 28.0 DC SINGLE LOCATION CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 2000.0 AC SINGLE LOCATION AND 6000.0 DC SINGLE LOCATION CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION CPRJ TRIP RELEASE METHOD THERMAL SINGLE LOCATION CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 138.0 SINGLE LOCATION CPRQ RESET METHOD MANUAL CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 PUSH BUTTON CPRW ACTUATOR FUNCTION TRIP-RESET CPRX ACTUATOR POSITION DESIGNATION AT POLE ONE CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SINGLE LOCATION CQJX NOMINAL THREAD SIZE 0.469 INCHES CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 4.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED VIBRATION RESISTANT AND SHOCK RESISTANT AND DUSTTIGHT AND CORROSION RESISTANT AND HUMIDITY RESISTANT AND EXPLOSION PROOF CRCF TRIP RELEASE AMBIENT TEMP RATING -55.0 DEG CELSIUS MINIMUM SINGLE LOCATION AND 121.0 DEG CELSIUS MAXIMUM SINGLE LOCATION FREQ FREQUENCY IN HERTZ 400.0 SINGLE LOCATION THSD THREAD SERIES DESIGNATOR UNS TTQY TERMINAL TYPE AND QUANTITY 2 TAB W/SCREW
MRC | Criteria | Characteristic |
---|---|---|
AAJE | THREAD PITCH DIAMETERS | +0.444/+0.447 INCHES |
AAQL | ||
ABXD | BUSHING LENGTH | 0.250 INCHES NOMINAL |
ADAQ | BODY LENGTH | 1.100 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.781 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.704 INCHES NOMINAL |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.218 INCHES NOMINAL |
AKPX | POLE QUANTITY | 1 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 35.0 AMPERES AC SINGLE LOCATION AND 35.0 AMPERES DC SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 120.0 AC SINGLE LOCATION AND 28.0 DC SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 2000.0 AC SINGLE LOCATION AND 6000.0 DC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | THERMAL SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 138.0 SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH BUTTON |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
CQJX | NOMINAL THREAD SIZE | 0.469 INCHES |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 4.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | VIBRATION RESISTANT AND SHOCK RESISTANT AND DUSTTIGHT AND CORROSION RESISTANT AND HUMIDITY RESISTANT AND EXPLOSION PROOF |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | -55.0 DEG CELSIUS MINIMUM SINGLE LOCATION AND 121.0 DEG CELSIUS MAXIMUM SINGLE LOCATION |
FREQ | FREQUENCY IN HERTZ | 400.0 SINGLE LOCATION |
THSD | THREAD SERIES DESIGNATOR | UNS |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB W/SCREW |