NSN 5925-01-254-9379 of Circuit Breaker - Parts Details
Alternative NSN: 5925012549379 |
Item Name: Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 012549379 |
NCB Code: USA (01) |
Manufacturers: Eaton Corp , Thales Training And Simulation Inc |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers AM1-A2-15-2, 6451005D, 64510005D under NSN 5925-01-254-9379 of Circuit Breaker manufactured by Eaton Corp, Thales Training And Simulation Inc.
Federal Supply Class of NSN 5925-01-254-9379 is FSC 5925 contains part details of Circuit Breakers. Quote for your desired part numbers.
Part Number's List for NSN 5925-01-254-9379, 5925012549379
Characteristics Data of NSN 5925012549379MRC Criteria Characteristic AAQL BODY STYLE SINGLE POLE TYPE ADAQ BODY LENGTH 2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM ADAT BODY WIDTH 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM ADTV CASE MATERIAL PLASTIC AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM AEGJ SWITCH CONTACT ARRANGEMENT SINGLE POLE, DOUBLE THROW AFJN FRAGILITY FACTOR MODERATELY RUGGED AJEC BOSS HEIGHT 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 2.611 INCHES NOMINAL AKPX POLE QUANTITY 1 APNQ ARC QUENCHING METHOD MAGNETIC BLOWOUT AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED HOLE BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE CMLP THREAD QUANTITY PER INCH 32 CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 15.0 AMPERES AC SINGLE LOCATION CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC SINGLE LOCATION CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC SINGLE LOCATION CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION CPRJ TRIP RELEASE METHOD MAGNETIC-HYDRAULIC SINGLE LOCATION CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 SINGLE LOCATION CPRQ RESET METHOD MANUAL CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE CPRW ACTUATOR FUNCTION TRIP-RESET CPRZ AUXILIARY SWITCH FUNCTION AND QUANTITY 1 ALARM CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SINGLE LOCATION CQJX NOMINAL THREAD SIZE 0.138 INCHES CQSM SWITCH LOCATION AND POSITION DESIGNATION INTERNAL AT POLE ONE CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 2.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED DUSTPROOF AND FUNGUS PROOF CRTK SWITCH TERMINAL TYPE TAB, SOLDER LUG CSSX SWITCH CURRENT RATING AND TYPE IN AMPS 10.0 AC AND 5.0 DC CSWP SWITCH VOLTAGE RATING AND TYPE IN VOLTS 250.0 AC AND 30.0 DC FREQ FREQUENCY IN HERTZ 60.0 SINGLE LOCATION THSD THREAD SERIES DESIGNATOR UNC TTQY TERMINAL TYPE AND QUANTITY 2 THREADED STUD
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | SINGLE POLE TYPE |
ADAQ | BODY LENGTH | 2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM |
AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJEC | BOSS HEIGHT | 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.611 INCHES NOMINAL |
AKPX | POLE QUANTITY | 1 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 15.0 AMPERES AC SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
CQSM | SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE ONE |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF AND FUNGUS PROOF |
CRTK | SWITCH TERMINAL TYPE | TAB, SOLDER LUG |
CSSX | SWITCH CURRENT RATING AND TYPE IN AMPS | 10.0 AC AND 5.0 DC |
CSWP | SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 250.0 AC AND 30.0 DC |
FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE LOCATION |
THSD | THREAD SERIES DESIGNATOR | UNC |
TTQY | TERMINAL TYPE AND QUANTITY | 2 THREADED STUD |