NSN 5925-01-285-9880 of Circuit Breaker - Parts Details
Alternative NSN: 5925012859880 |
Item Name: Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 012859880 |
NCB Code: USA (01) |
Manufacturers: Sensata Technologies Inc |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers MPL-111-1-66-453 under NSN 5925-01-285-9880 of Circuit Breaker manufactured by Sensata Technologies Inc.
Federal Supply Class of NSN 5925-01-285-9880 is FSC 5925 contains part details of Circuit Breakers. Quote for your desired part numbers.
Part Number's List for NSN 5925-01-285-9880, 5925012859880
-
Part No Manufacturer Item Name QTY RFQ MPL-111-1-66-453 Sensata Technologies Inc circuit breaker Avl RFQ
Characteristics Data of NSN 5925012859880MRC Criteria Characteristic AAQL BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE ADAQ BODY LENGTH 2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM ADAT BODY WIDTH 2.250 INCHES MAXIMUM ADTV CASE MATERIAL PLASTIC AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.925 INCHES MINIMUM AND 1.955 INCHES MAXIMUM AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM AEHA DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM AFJN FRAGILITY FACTOR MODERATELY RUGGED AJEC BOSS HEIGHT 0.135 INCHES MINIMUM AND 0.165 INCHES MAXIMUM AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 2.470 INCHES MINIMUM AND 2.500 INCHES MAXIMUM AKPX POLE QUANTITY 3 APNQ ARC QUENCHING METHOD MAGNETIC BLOWOUT AXHR MOUNTING FACILITY TYPE AND QUANTITY 6 THREADED HOLE BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE CMLP THREAD QUANTITY PER INCH 32 CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 45.0 AMPERES AC ALL LOCATIONS CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC ALL LOCATIONS CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC ALL LOCATIONS CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS CPRJ TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 ALL LOCATIONS CPRQ RESET METHOD MANUAL CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE CPRT MANUAL ACTUATOR TYPE AND QUANTITY 3 TOGGLE CPRW ACTUATOR FUNCTION TRIP-RESET CPRX ACTUATOR POSITION DESIGNATION AT EACH POLE CPRY EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, AND THREE LINKED CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS CQJX NOMINAL THREAD SIZE 0.138 INCHES CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 9.500 MINIMUM AT 200 PCT ALL LOCATIONS AND 70.000 MAXIMUM AT 200 PCT ALL LOCATIONS CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED DUSTPROOF FREQ FREQUENCY IN HERTZ 60.0 ALL LOCATIONS THSD THREAD SERIES DESIGNATOR UNC TTQY TERMINAL TYPE AND QUANTITY 6 THREADED STUD
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
ADAQ | BODY LENGTH | 2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.250 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.925 INCHES MINIMUM AND 1.955 INCHES MAXIMUM |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJEC | BOSS HEIGHT | 0.135 INCHES MINIMUM AND 0.165 INCHES MAXIMUM |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.470 INCHES MINIMUM AND 2.500 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 3 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 THREADED HOLE |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 45.0 AMPERES AC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 3 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE, TWO, AND THREE LINKED |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 9.500 MINIMUM AT 200 PCT ALL LOCATIONS AND 70.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
THSD | THREAD SERIES DESIGNATOR | UNC |
TTQY | TERMINAL TYPE AND QUANTITY | 6 THREADED STUD |