NSN 5925-01-300-7491 of Circuit Breaker - Parts Details
Alternative NSN: 5925013007491 |
Item Name: Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 013007491 |
NCB Code: USA (01) |
Manufacturers: Eaton Corp , Thales Training And Simulation Inc |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers AM1S AA2 A A 07 D A 52 30 2, 64510016D under NSN 5925-01-300-7491 of Circuit Breaker manufactured by Eaton Corp, Thales Training And Simulation Inc.
Federal Supply Class of NSN 5925-01-300-7491 is FSC 5925 contains part details of Circuit Breakers. Quote for your desired part numbers.
Part Number's List for NSN 5925-01-300-7491, 5925013007491
-
Part No Manufacturer Item Name QTY RFQ AM1S AA2 A A 07 D A 52 30 2 Eaton Corp circuit breaker Avl RFQ 64510016D Thales Training And Simulation Inc circuit breaker Avl RFQ
Characteristics Data of NSN 5925013007491MRC Criteria Characteristic AAQL BODY STYLE SINGLE POLE TYPE ADAQ BODY LENGTH 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM ADAT BODY WIDTH 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM ADTV CASE MATERIAL PLASTIC AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM AFJN FRAGILITY FACTOR MODERATELY RUGGED AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 2.549 INCHES MINIMUM AND 2.673 INCHES MAXIMUM AKPX POLE QUANTITY 1 APNQ ARC QUENCHING METHOD MAGNETIC BLOWOUT AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED HOLE CMLP THREAD QUANTITY PER INCH 32 CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 30.0 AMPERES AC SINGLE LOCATION CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC SINGLE LOCATION CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC SINGLE LOCATION CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION CPRQ RESET METHOD MANUAL CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE CPRW ACTUATOR FUNCTION TRIP-RESET CPRX ACTUATOR POSITION DESIGNATION AT POLE ONE CQJX NOMINAL THREAD SIZE 0.138 INCHES CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 2.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED DUSTPROOF AND FUNGUS PROOF FREQ FREQUENCY IN HERTZ 60.0 SINGLE LOCATION THSD THREAD SERIES DESIGNATOR UNC TTQY TERMINAL TYPE AND QUANTITY 2 THREADED STUD AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE AJEC BOSS HEIGHT 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM CPRJ TRIP RELEASE METHOD MAGNETIC-HYDRAULIC SINGLE LOCATION CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 SINGLE LOCATION CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SINGLE LOCATION
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | SINGLE POLE TYPE |
ADAQ | BODY LENGTH | 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.549 INCHES MINIMUM AND 2.673 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 1 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 30.0 AMPERES AC SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF AND FUNGUS PROOF |
FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE LOCATION |
THSD | THREAD SERIES DESIGNATOR | UNC |
TTQY | TERMINAL TYPE AND QUANTITY | 2 THREADED STUD |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
AJEC | BOSS HEIGHT | 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |