NSN 5925-01-327-5727 of Circuit Breaker - Parts Details
Alternative NSN: 5925013275727 |
Item Name: Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 013275727 |
NCB Code: USA (01) |
Manufacturers: Perkin Elmer Corp The , Sensata Technologies Inc , Henley Marine Services |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers IEL11161-25.0-01, IEL11-1-61-25.0-01-V, 28075311 under NSN 5925-01-327-5727 of Circuit Breaker manufactured by Perkin Elmer Corp The, Sensata Technologies Inc, Henley Marine Services.
Federal Supply Class of NSN 5925-01-327-5727 is FSC 5925 contains part details of Circuit Breakers. Quote for your desired part numbers.
Part Number's List for NSN 5925-01-327-5727, 5925013275727
-
Part No Manufacturer Item Name QTY RFQ IEL11161-25.0-01 Perkin Elmer Corp The circuit breaker Avl RFQ IEL11161-25.0-01 Sensata Technologies Inc circuit breaker Avl RFQ IEL11-1-61-25.0-01-V Sensata Technologies Inc circuit breaker Avl RFQ 28075311 Henley Marine Services circuit breaker Avl RFQ
Characteristics Data of NSN 5925013275727MRC Criteria Characteristic AAQL BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE ADTV CASE MATERIAL PLASTIC AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.933 INCHES MINIMUM AND 1.943 INCHES MAXIMUM AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.055 INCHES MINIMUM AND 2.065 INCHES MAXIMUM AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 1.996 INCHES MINIMUM AND 2.006 INCHES MAXIMUM AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 THREADED HOLE CMLP THREAD QUANTITY PER INCH 32 CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC ALL LOCATIONS CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 2000.0 AC ALL LOCATIONS CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS CPRJ TRIP RELEASE METHOD MAGNETIC-HYDRAULIC ALL LOCATIONS CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE CPRW ACTUATOR FUNCTION TRIP-RESET CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.130 MINIMUM AT 200 PCT ALL LOCATIONS AND 3.000 MAXIMUM AT 200 PCT ALL LOCATIONS CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED MOISTURE RESISTANT AND SALT SPRAY PROOF AND SHOCKPROOF FREQ FREQUENCY IN HERTZ 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS ADAT BODY WIDTH 1.515 INCHES MAXIMUM AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM AEHA DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM AJEC BOSS HEIGHT 0.135 INCHES MINIMUM AND 0.145 INCHES MAXIMUM CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 25.0 AMPERES AC ALL LOCATIONS CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 ALL LOCATIONS CPRQ RESET METHOD MANUAL CPRX ACTUATOR POSITION DESIGNATION AT POLE ONE THSD THREAD SERIES DESIGNATOR UNC APNQ ARC QUENCHING METHOD MAGNETIC BLOWOUT BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE ADAQ BODY LENGTH 2.485 INCHES MINIMUM AND 2.495 INCHES MAXIMUM AFJN FRAGILITY FACTOR MODERATELY RUGGED AKPX POLE QUANTITY 2 CQJX NOMINAL THREAD SIZE 0.138 INCHES TTQY TERMINAL TYPE AND QUANTITY 4 THREADED STUD
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
ADTV | CASE MATERIAL | PLASTIC |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.933 INCHES MINIMUM AND 1.943 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.055 INCHES MINIMUM AND 2.065 INCHES MAXIMUM |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.996 INCHES MINIMUM AND 2.006 INCHES MAXIMUM |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 2000.0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.130 MINIMUM AT 200 PCT ALL LOCATIONS AND 3.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | MOISTURE RESISTANT AND SALT SPRAY PROOF AND SHOCKPROOF |
FREQ | FREQUENCY IN HERTZ | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
ADAT | BODY WIDTH | 1.515 INCHES MAXIMUM |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM |
AJEC | BOSS HEIGHT | 0.135 INCHES MINIMUM AND 0.145 INCHES MAXIMUM |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 25.0 AMPERES AC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
THSD | THREAD SERIES DESIGNATOR | UNC |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
ADAQ | BODY LENGTH | 2.485 INCHES MINIMUM AND 2.495 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AKPX | POLE QUANTITY | 2 |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
TTQY | TERMINAL TYPE AND QUANTITY | 4 THREADED STUD |