NSN 5925-01-340-6228 of Circuit Breaker - Parts Details
Alternative NSN: 5925013406228 |
Item Name: Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 013406228 |
NCB Code: USA (01) |
Manufacturers: Sensata Technologies Inc |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers PP21-62F-5.00A-0A-S under NSN 5925-01-340-6228 of Circuit Breaker manufactured by Sensata Technologies Inc.
Federal Supply Class of NSN 5925-01-340-6228 is FSC 5925 contains part details of Circuit Breakers. Quote for your desired part numbers.
Part Number's List for NSN 5925-01-340-6228, 5925013406228
-
Part No Manufacturer Item Name QTY RFQ PP21-62F-5.00A-0A-S Sensata Technologies Inc circuit breaker Avl RFQ
Characteristics Data of NSN 5925013406228MRC Criteria Characteristic AAQL BODY STYLE SINGLE POLE TYPE ABXD BUSHING LENGTH 0.400 INCHES NOMINAL ADAT BODY WIDTH 1.375 INCHES NOMINAL ADTV CASE MATERIAL PLASTIC AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.625 INCHES NOMINAL AFJN FRAGILITY FACTOR MODERATELY RUGGED AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 0.960 INCHES NOMINAL AKPX POLE QUANTITY 2 APNQ ARC QUENCHING METHOD MAGNETIC BLOWOUT AXHR MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE CMLP THREAD QUANTITY PER INCH 32 CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC ALL LOCATIONS CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS CPRJ TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 PUSH-PULL CPRW ACTUATOR FUNCTION TRIP-RESET CQJX NOMINAL THREAD SIZE 0.375 INCHES CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 1.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 15.000 MAXIMUM AT 200 PCT ALL LOCATIONS CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED DUSTPROOF AND FUNGUS PROOF FEAT SPECIAL FEATURES ITEM INCLUDES INERTIA DELAY FREQ FREQUENCY IN HERTZ 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS THSD THREAD SERIES DESIGNATOR UNEF ADAQ BODY LENGTH 1.304 INCHES NOMINAL CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 ALL LOCATIONS CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 5.0 AMPERES AC ALL LOCATIONS CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE BBRJ SPECIAL HANDLING FEATURE MAGNETIC CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC ALL LOCATIONS CPRQ RESET METHOD MANUAL CPRX ACTUATOR POSITION DESIGNATION BETWEEN POLE ONE AND TWO TTQY TERMINAL TYPE AND QUANTITY 4 TAB W/SCREW
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | SINGLE POLE TYPE |
ABXD | BUSHING LENGTH | 0.400 INCHES NOMINAL |
ADAT | BODY WIDTH | 1.375 INCHES NOMINAL |
ADTV | CASE MATERIAL | PLASTIC |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.625 INCHES NOMINAL |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 0.960 INCHES NOMINAL |
AKPX | POLE QUANTITY | 2 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CQJX | NOMINAL THREAD SIZE | 0.375 INCHES |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 1.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 15.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF AND FUNGUS PROOF |
FEAT | SPECIAL FEATURES | ITEM INCLUDES INERTIA DELAY |
FREQ | FREQUENCY IN HERTZ | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
THSD | THREAD SERIES DESIGNATOR | UNEF |
ADAQ | BODY LENGTH | 1.304 INCHES NOMINAL |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 5.0 AMPERES AC ALL LOCATIONS |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRX | ACTUATOR POSITION DESIGNATION | BETWEEN POLE ONE AND TWO |
TTQY | TERMINAL TYPE AND QUANTITY | 4 TAB W/SCREW |