NSN 5925-01-392-2836 of Circuit Breaker - Parts Details
Alternative NSN: 5925013922836 |
Item Name: Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 013922836 |
NCB Code: USA (01) |
Manufacturers: General Electric Company , Hill Ross Controls Corp |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers TB43400AF14, 0302-1202-00 under NSN 5925-01-392-2836 of Circuit Breaker manufactured by General Electric Company, Hill Ross Controls Corp.
Federal Supply Class of NSN 5925-01-392-2836 is FSC 5925 contains part details of Circuit Breakers. Quote for your desired part numbers.
Part Number's List for NSN 5925-01-392-2836, 5925013922836
-
Part No Manufacturer Item Name QTY RFQ TB43400AF14 General Electric Company circuit breaker Avl RFQ 0302-1202-00 Hill Ross Controls Corp circuit breaker Avl RFQ
Characteristics Data of NSN 5925013922836MRC Criteria Characteristic ABHP Overall Length 16.125 INCHES NOMINAL AKPX Pole Quantity 3 CPRF Operating Voltage Type And Rating Per Pole In Volts 600.0 DC ALL LOCATIONS CPRG Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps 200.000 AC ALL LOCATIONS CPRJ Trip Release Method THERMAL-MAGNETIC ALL LOCATIONS CPRH Circuit Protection Type OVERCURRENT ALL LOCATIONS CPRN Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent 125.0 ALL LOCATIONS CRCF Trip Release Ambient Temp Rating 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS CPRQ Reset Method MANUAL CPRT Manual Actuator Type And Quantity 1 TOGGLE AXHR Mounting Facility Type And Quantity 4 UNTHREADED HOLE CPRR Main Contact Tripping Mechanism Type TRIP FREE CPRX Actuator Position Designation AT POLE TWO ADTV Case Material PLASTIC TTQY Terminal Type And Quantity 6 COMPRESSION AAQL Body Style ABMK Overall Width 8.250 INCHES NOMINAL ABKW Overall Height 4.500 INCHES NOMINAL CPLM Maximum Continuous Load Current Rating Per Pole 400.0 AMPERES AC ALL LOCATIONS MRC Decoded Requirement Clear Text Reply CPRL Trip Release Characteristic INSTANTANEOUS ALL LOCATIONS CPRW Actuator Function TRIP-RESET AEBV Unthreaded Mounting Hole Diameter 0.196 INCHES NOMINAL
MRC | Criteria | Characteristic |
---|---|---|
ABHP | Overall Length | 16.125 INCHES NOMINAL |
AKPX | Pole Quantity | 3 |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 600.0 DC ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 200.000 AC ALL LOCATIONS |
CPRJ | Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CRCF | Trip Release Ambient Temp Rating | 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
AXHR | Mounting Facility Type And Quantity | 4 UNTHREADED HOLE |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRX | Actuator Position Designation | AT POLE TWO |
ADTV | Case Material | PLASTIC |
TTQY | Terminal Type And Quantity | 6 COMPRESSION |
AAQL | Body Style | |
ABMK | Overall Width | 8.250 INCHES NOMINAL |
ABKW | Overall Height | 4.500 INCHES NOMINAL |
CPLM | Maximum Continuous Load Current Rating Per Pole | 400.0 AMPERES AC ALL LOCATIONS |
MRC | Decoded Requirement | Clear Text Reply |
CPRL | Trip Release Characteristic | INSTANTANEOUS ALL LOCATIONS |
CPRW | Actuator Function | TRIP-RESET |
AEBV | Unthreaded Mounting Hole Diameter | 0.196 INCHES NOMINAL |