NSN 5925-01-394-5365 of Circuit Breaker - Parts Details
Alternative NSN: 5925013945365 |
Item Name: Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 013945365 |
NCB Code: USA (01) |
Manufacturers: Sensata Technologies Inc , Genisco Filter Corp |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers UPL-111-1REC3-62-303, UPL-111-1REC3-62 under NSN 5925-01-394-5365 of Circuit Breaker manufactured by Sensata Technologies Inc, Genisco Filter Corp.
Federal Supply Class of NSN 5925-01-394-5365 is FSC 5925 contains part details of Circuit Breakers. Quote for your desired part numbers.
Part Number's List for NSN 5925-01-394-5365, 5925013945365
-
Part No Manufacturer Item Name QTY RFQ UPL-111-1REC3-62-303 Sensata Technologies Inc circuit breaker Avl RFQ UPL-111-1REC3-62 Genisco Filter Corp circuit breaker Avl RFQ
Characteristics Data of NSN 5925013945365MRC Criteria Characteristic AEBY Distance Between Centerlines Of Mounting Facilities Parallel To Body Length 2.060 INCHES NOMINAL CPLM Maximum Continuous Load Current Rating Per Pole 30.0 AMPERES AC ALL LOCATIONS AJEC Boss Height 0.150 INCHES NOMINAL AKPX Pole Quantity 3 CPRG Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps 1000.0 AC ALL LOCATIONS CPRH Circuit Protection Type OVERCURRENT ALL LOCATIONS FREQ Frequency In Hertz 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS CPRJ Trip Release Method MAGNETIC ALL LOCATIONS CPRL Trip Release Characteristic TIME DELAY ALL LOCATIONS CPRQ Reset Method MANUAL AEHA Distance Between Centerlines Of Mounting Facilities Parallel To Body Width 0.750 INCHES NOMINAL AXHR Mounting Facility Type And Quantity 6 THREADED HOLE CPRR Main Contact Tripping Mechanism Type TRIP FREE CPRW Actuator Function TRIP-RESET CPRY External Actuator Linkage Arrangement ONE, TWO, AND THREE LINKED ADAT Body Width 2.265 INCHES MAXIMUM CPRT Manual Actuator Type And Quantity 3 TOGGLE THSD Thread Series Designator UNC CPSM Internal Trip Release Configuration SERIES TRIP ALL LOCATIONS TTQY Terminal Type And Quantity 6 THREADED STUD CQJX Nominal Thread Size 0.138 INCHES AJWX Mounting Surface To Terminal End Distance 2.645 INCHES NOMINAL ADTV Case Material PLASTIC ADAQ Body Length 2.530 INCHES MAXIMUM AEBP Center To Center Distance Between Terminals Parallel To Length 1.940 INCHES NOMINAL AAQL Body Style MULTIPOLE-MULTIPLE ACTUATOR TYPE AEBQ Center To Center Distance Between Terminals Parallel To Width 0.750 INCHES NOMINAL CPRF Operating Voltage Type And Rating Per Pole In Volts 250.0 AC ALL LOCATIONS CQWN Trip Delay Time In Seconds Per Rated Continuous Current 2.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 22.000 MAXIMUM AT 200 PCT ALL LOCATIONS MRC Decoded Requirement Clear Text Reply CPRN Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent 125.0 ALL LOCATIONS CPRX Actuator Position Designation AT EACH POLE
MRC | Criteria | Characteristic |
---|---|---|
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.060 INCHES NOMINAL |
CPLM | Maximum Continuous Load Current Rating Per Pole | 30.0 AMPERES AC ALL LOCATIONS |
AJEC | Boss Height | 0.150 INCHES NOMINAL |
AKPX | Pole Quantity | 3 |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
FREQ | Frequency In Hertz | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.750 INCHES NOMINAL |
AXHR | Mounting Facility Type And Quantity | 6 THREADED HOLE |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRW | Actuator Function | TRIP-RESET |
CPRY | External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
ADAT | Body Width | 2.265 INCHES MAXIMUM |
CPRT | Manual Actuator Type And Quantity | 3 TOGGLE |
THSD | Thread Series Designator | UNC |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
TTQY | Terminal Type And Quantity | 6 THREADED STUD |
CQJX | Nominal Thread Size | 0.138 INCHES |
AJWX | Mounting Surface To Terminal End Distance | 2.645 INCHES NOMINAL |
ADTV | Case Material | PLASTIC |
ADAQ | Body Length | 2.530 INCHES MAXIMUM |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.940 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.750 INCHES NOMINAL |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 22.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
MRC | Decoded Requirement | Clear Text Reply |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRX | Actuator Position Designation | AT EACH POLE |