NSN 5925-01-462-6069 of Circuit Breaker - Parts Details
Alternative NSN: 5925014626069 |
Item Name: Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 014626069 |
NCB Code: USA (01) |
Manufacturers: Tyco Electronics |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers W92X112-50 under NSN 5925-01-462-6069 of Circuit Breaker manufactured by Tyco Electronics.
Federal Supply Class of NSN 5925-01-462-6069 is FSC 5925 contains part details of Circuit Breakers. Quote for your desired part numbers.
Part Number's List for NSN 5925-01-462-6069, 5925014626069
-
Part No Manufacturer Item Name QTY RFQ W92X112-50 Tyco Electronics circuit breaker Avl RFQ
Characteristics Data of NSN 5925014626069MRC Criteria Characteristic AAQL BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE ADTV CASE MATERIAL PLASTIC AGAV END ITEM IDENTIFICATION P/N 9702A1000-1 PILOTHOUSE CONSOLE ONBOARD 87 FT WPB COAST GUARD VESSELS AKPX POLE QUANTITY 2 AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 SLOT CMLP THREAD QUANTITY PER INCH 32 CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 20.0 AMPERES AC ALL LOCATIONS CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 5000.0 AC ALL LOCATIONS CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS CPRJ TRIP RELEASE METHOD MAGNETIC-HYDRAULIC ALL LOCATIONS CPRL TRIP RELEASE CHARACTERISTIC INSTANTANEOUS ALL LOCATIONS CPRQ RESET METHOD MANUAL CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE CQQC TRIP RELEASE DUTY CYCLE CONTINUOUS ALL LOCATIONS
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
ADTV | CASE MATERIAL | PLASTIC |
AGAV | END ITEM IDENTIFICATION | P/N 9702A1000-1 PILOTHOUSE CONSOLE ONBOARD 87 FT WPB COAST GUARD VESSELS |
AKPX | POLE QUANTITY | 2 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 SLOT |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 20.0 AMPERES AC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CQQC | TRIP RELEASE DUTY CYCLE | CONTINUOUS ALL LOCATIONS |