NSN 5930-00-821-3316 of Switch Thermostatic - Parts Details
Alternative NSN: 5930008213316 |
Item Name: Switch Thermostatic |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5930 Switches |
NIIN: 008213316 |
NCB Code: USA (00) |
Manufacturers: Thermodisc Incorporated , Essex Group Inc , Tektronix Inc , Texas Instrument Inc |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers SE11S6261, SE11-6261, 430354, 36T21 S3773, 260-120 under NSN 5930-00-821-3316 of Switch Thermostatic manufactured by Thermodisc Incorporated, Essex Group Inc, Tektronix Inc, Texas Instrument Inc.
Federal Supply Class of NSN 5930-00-821-3316 is FSC 5930 contains part details of Switches. Quote for your desired part numbers.
Part Number's List for NSN 5930-00-821-3316, 5930008213316
-
Part No Manufacturer Item Name QTY RFQ SE11S6261 Thermodisc Incorporated switch thermostatic Avl RFQ SE11-6261 Thermodisc Incorporated switch thermostatic Avl RFQ 430354 Essex Group Inc switch thermostatic Avl RFQ 36T21 S3773 Thermodisc Incorporated switch thermostatic Avl RFQ 260-120 Tektronix Inc switch thermostatic Avl RFQ 260-0120-00 Tektronix Inc switch thermostatic Avl RFQ 20700L63-184 Texas Instrument Inc switch thermostatic Avl RFQ 110086 Essex Group Inc switch thermostatic Avl RFQ 110-354 Essex Group Inc switch thermostatic Avl RFQ
Characteristics Data of NSN 5930008213316MRC Criteria Characteristic ABHP III OVERALL LENGTH 1.688 INCHES NOMINAL ABKW OVERALL HEIGHT 0.313 INCHES NOMINAL ABPM BODY DIAMETER 1.219 INCHES NOMINAL ADAU BODY HEIGHT 0.312 INCHES NOMINAL AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.140 INCHES MINIMUM AND 0.148 INCHES MAXIMUM AEJN DISTANCE BETWEEN MOUNTING FACILITY CENTERS 1.375 INCHES NOMINAL AKBY TEMP SENSING ELEMENT TYPE INTERNAL SENSOR AWTN OPERATING TEMP RATING 130.0 DEG FAHRENHEIT MINIMUM AND 144.0 DEG FAHRENHEIT MAXIMUM AXGY MOUNTING METHOD BRACKET AND UNTHREADED HOLE CQGB CONTACT ACTION STIMULUS INCREASE CQYJ MOUNTING FACILITY PATTERN TWO POSITION IN-LINE CSCF TERMINAL TYPE TAB W/SCREW CTHF CONTACT LOAD CURRENT RATING 8.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE CTYX CONTACT STIMULUS RATING 137.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 122.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT CTZB CONTACT VOLTAGE RATING IN VOLTS 120.0 AC AT SEA LEVEL SINGLE VOLTAGE FREQ FREQUENCY IN HERTZ 60.0 SINGLE VOLTAGE MEDA MEDIA FOR WHICH DESIGNED GAS OR LIQUID STYL III STYLE DESIGNATOR DISC W/FLANGE CRLD NONPILE-UP CONTACT ARRANGEMENT 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION CTYC CONTACT ADJUSTABILITY DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE
MRC | Criteria | Characteristic |
---|---|---|
ABHP | III OVERALL LENGTH | 1.688 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 0.313 INCHES NOMINAL |
ABPM | BODY DIAMETER | 1.219 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0.312 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.140 INCHES MINIMUM AND 0.148 INCHES MAXIMUM |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.375 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
AWTN | OPERATING TEMP RATING | 130.0 DEG FAHRENHEIT MINIMUM AND 144.0 DEG FAHRENHEIT MAXIMUM |
AXGY | MOUNTING METHOD | BRACKET AND UNTHREADED HOLE |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
CSCF | TERMINAL TYPE | TAB W/SCREW |
CTHF | CONTACT LOAD CURRENT RATING | 8.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
CTYX | CONTACT STIMULUS RATING | 137.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 122.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 120.0 AC AT SEA LEVEL SINGLE VOLTAGE |
FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
STYL | III STYLE DESIGNATOR | DISC W/FLANGE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |