NSN 5930-00-952-8845 of Switch Thermostatic - Parts Details
Alternative NSN: 5930009528845 |
Item Name: Switch Thermostatic |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5930 Switches |
NIIN: 009528845 |
NCB Code: USA (00) |
Manufacturers: Gulf Aerospace Inc , Harsco Corporation , United Electric Controls Company , Hollingsworth John R Co |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers 170-011, 170-065, C47-102, C47-107, C47-9197 under NSN 5930-00-952-8845 of Switch Thermostatic manufactured by Gulf Aerospace Inc, Harsco Corporation, United Electric Controls Company, Hollingsworth John R Co.
Federal Supply Class of NSN 5930-00-952-8845 is FSC 5930 contains part details of Switches. Quote for your desired part numbers.
Part Number's List for NSN 5930-00-952-8845, 5930009528845
-
Part No Manufacturer Item Name QTY RFQ 170-011 Gulf Aerospace Inc switch thermostatic Avl RFQ 170-065 Harsco Corporation switch thermostatic Avl RFQ C47-102 United Electric Controls Company switch thermostatic Avl RFQ C47-107 United Electric Controls Company switch thermostatic Avl RFQ C47-9197 United Electric Controls Company switch thermostatic Avl RFQ C54S-14708 United Electric Controls Company switch thermostatic Avl RFQ JHP37-21-3 Hollingsworth John R Co switch thermostatic Avl RFQ JHP95-178 Hollingsworth John R Co switch thermostatic Avl RFQ MODEL102TYPEC47 United Electric Controls Company switch thermostatic Avl RFQ
Characteristics Data of NSN 5930009528845MRC Criteria Characteristic ABHP III OVERALL LENGTH 1.938 INCHES NOMINAL ABKW OVERALL HEIGHT 3.688 INCHES NOMINAL ABMK OVERALL WIDTH 0.984 INCHES NOMINAL AKBY TEMP SENSING ELEMENT TYPE BELLOWS AXGY MOUNTING METHOD IMMERSION WELL CQGB CONTACT ACTION STIMULUS INCREASE CRLD NONPILE-UP CONTACT ARRANGEMENT 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY CSCF TERMINAL TYPE SCREW CTHF CONTACT LOAD CURRENT RATING 15.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE CTYC CONTACT ADJUSTABILITY ACTUATION POINT ADJUSTABLE CTYM CONTACT ADJUSTMENT RANGE +0.00/+225.00 ACTUATION POINT DEGREES FAHRENHEIT CTYS CONTACT ADJUSTMENT TYPE INTERNAL ACTUATION POINT KNOB CTZB CONTACT VOLTAGE RATING IN VOLTS 230.0 AC AT SEA LEVEL SINGLE VOLTAGE
MRC | Criteria | Characteristic |
---|---|---|
ABHP | III OVERALL LENGTH | 1.938 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 3.688 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 0.984 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | BELLOWS |
AXGY | MOUNTING METHOD | IMMERSION WELL |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CSCF | TERMINAL TYPE | SCREW |
CTHF | CONTACT LOAD CURRENT RATING | 15.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
CTYM | CONTACT ADJUSTMENT RANGE | +0.00/+225.00 ACTUATION POINT DEGREES FAHRENHEIT |
CTYS | CONTACT ADJUSTMENT TYPE | INTERNAL ACTUATION POINT KNOB |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 AC AT SEA LEVEL SINGLE VOLTAGE |