NSN 5930-01-067-2984 of Switch Thermostatic - Parts Details
Alternative NSN: 5930010672984 |
Item Name: Switch Thermostatic |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5930 Switches |
NIIN: 010672984 |
NCB Code: USA (01) |
Manufacturers: Ranco Controls , Ranco Management Corp , Sweden Freezer Inc |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers 020-8001, 0-145-15 under NSN 5930-01-067-2984 of Switch Thermostatic manufactured by Ranco Controls, Ranco Management Corp, Sweden Freezer Inc.
Federal Supply Class of NSN 5930-01-067-2984 is FSC 5930 contains part details of Switches. Quote for your desired part numbers.
Part Number's List for NSN 5930-01-067-2984, 5930010672984
Characteristics Data of NSN 5930010672984MRC Criteria Characteristic AEVT CAPILLARY TUBE LENGTH 60.0 INCHES NOMINAL AKBY TEMP SENSING ELEMENT TYPE CAPILLARY TUBE-BULB AXGY MOUNTING METHOD BRACKET CQGB CONTACT ACTION STIMULUS INCREASE CRLD NONPILE-UP CONTACT ARRANGEMENT 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION CTHF CONTACT LOAD CURRENT RATING 2.3 AMPERES RESISTIVE LOAD SECOND VOLTAGE CTHF CONTACT LOAD CURRENT RATING 24.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE CTHF CONTACT LOAD CURRENT RATING 4.6 AMPERES RESISTIVE LOAD THIRD VOLTAGE CTYC CONTACT ADJUSTABILITY DEACTUATION POINT ADJUSTABLE, PRESET AND ACTUATION POINT ADJUSTABLE, PRESET CTYM CONTACT ADJUSTMENT RANGE +0.00/+55.00 ACTUATION POINT DEGREES FAHRENHEIT AND +0.00/+55.00 DEACTUATION POINT DEGREES FAHRENHEIT CTYS CONTACT ADJUSTMENT TYPE EXTERNAL DEACTUATION POINT KNOB AND EXTERNAL ACTUATION POINT KNOB CTYX CONTACT STIMULUS RATING 29.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 13.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT CTZB CONTACT VOLTAGE RATING IN VOLTS 120.0 DC AT SEA LEVEL THIRD VOLTAGE CTZB CONTACT VOLTAGE RATING IN VOLTS 240.0 AC AT SEA LEVEL FIRST VOLTAGE CTZB CONTACT VOLTAGE RATING IN VOLTS 240.0 DC AT SEA LEVEL SECOND VOLTAGE MEDA MEDIA FOR WHICH DESIGNED GAS OR LIQUID
MRC | Criteria | Characteristic |
---|---|---|
AEVT | CAPILLARY TUBE LENGTH | 60.0 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
AXGY | MOUNTING METHOD | BRACKET |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
CTHF | CONTACT LOAD CURRENT RATING | 2.3 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 24.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 4.6 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE, PRESET AND ACTUATION POINT ADJUSTABLE, PRESET |
CTYM | CONTACT ADJUSTMENT RANGE | +0.00/+55.00 ACTUATION POINT DEGREES FAHRENHEIT AND +0.00/+55.00 DEACTUATION POINT DEGREES FAHRENHEIT |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT KNOB AND EXTERNAL ACTUATION POINT KNOB |
CTYX | CONTACT STIMULUS RATING | 29.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 13.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 120.0 DC AT SEA LEVEL THIRD VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 240.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 240.0 DC AT SEA LEVEL SECOND VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |