NSN 5930-01-127-8158 of Switch Liquid Level - Parts Details
Alternative NSN: 5930011278158 |
Item Name: Switch Liquid Level |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5930 Switches |
NIIN: 011278158 |
NCB Code: USA (01) |
Manufacturers: Gems Sensors Inc |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers LS-800-2-SS-BN, A4787 under NSN 5930-01-127-8158 of Switch Liquid Level manufactured by Gems Sensors Inc.
Federal Supply Class of NSN 5930-01-127-8158 is FSC 5930 contains part details of Switches. Quote for your desired part numbers.
Part Number's List for NSN 5930-01-127-8158, 5930011278158
-
Part No Manufacturer Item Name QTY RFQ LS-800-2-SS-BN Gems Sensors Inc switch liquid level Avl RFQ A4787 Gems Sensors Inc switch liquid level Avl RFQ
Characteristics Data of NSN 5930011278158MRC Criteria Characteristic ABJP POWER CABLE LENGTH 24.000 INCHES NOMINAL ACYN AC VOLTAGE RATING UNABLE TO DECODE ACYR DC VOLTAGE RATING UNABLE TO DECODE ACZB FREQUENCY RATING UNABLE TO DECODE ADAV OVERALL DIAMETER 1.250 INCHES NOMINAL AFLW ACTUATION METHOD BUOYANCY AGBD ELECTRICAL CONNECTION TYPE CABLE ALSF INTERNAL BATTERY ACCOMMODATION NOT INCLUDED APGW CURRENT RATING AT MAXIMUM RATED VOLTAGE 0.4 AMPERES RESISTIVE LOAD APGY VOLTAGE RATING AT MAXIMUM RATED CURRENT 30.0 VOLTS AWAE FLOAT QUANTITY 1 AWTN OPERATING TEMP RATING 180.0 DEG FAHRENHEIT NOMINAL AXGY MOUNTING METHOD THREAD BBJX MOUNTING POSITION VERTICAL BJKC MAXIMUM CURRENT RATING 3.0 AMPERES RESISTIVE LOAD BJKD CONTACT ARRANGEMENT SPST,NORMALLY CLOSED BJKG RELAY NOT INCLUDED BJKP MOUNTING DIMENSIONS MTD BY ONE 1.250 IN. DIA NPT PLUG BJKQ TANK INSERTION LENGTH 28.000 INCHES NOMINAL FAAZ PHASE UNABLE TO DECODE
MRC | Criteria | Characteristic |
---|---|---|
ABJP | POWER CABLE LENGTH | 24.000 INCHES NOMINAL |
ACYN | AC VOLTAGE RATING | UNABLE TO DECODE |
ACYR | DC VOLTAGE RATING | UNABLE TO DECODE |
ACZB | FREQUENCY RATING | UNABLE TO DECODE |
ADAV | OVERALL DIAMETER | 1.250 INCHES NOMINAL |
AFLW | ACTUATION METHOD | BUOYANCY |
AGBD | ELECTRICAL CONNECTION TYPE | CABLE |
ALSF | INTERNAL BATTERY ACCOMMODATION | NOT INCLUDED |
APGW | CURRENT RATING AT MAXIMUM RATED VOLTAGE | 0.4 AMPERES RESISTIVE LOAD |
APGY | VOLTAGE RATING AT MAXIMUM RATED CURRENT | 30.0 VOLTS |
AWAE | FLOAT QUANTITY | 1 |
AWTN | OPERATING TEMP RATING | 180.0 DEG FAHRENHEIT NOMINAL |
AXGY | MOUNTING METHOD | THREAD |
BBJX | MOUNTING POSITION | VERTICAL |
BJKC | MAXIMUM CURRENT RATING | 3.0 AMPERES RESISTIVE LOAD |
BJKD | CONTACT ARRANGEMENT | SPST,NORMALLY CLOSED |
BJKG | RELAY | NOT INCLUDED |
BJKP | MOUNTING DIMENSIONS | MTD BY ONE 1.250 IN. DIA NPT PLUG |
BJKQ | TANK INSERTION LENGTH | 28.000 INCHES NOMINAL |
FAAZ | PHASE | UNABLE TO DECODE |