NSN 5950-00-103-5117 of Transformer Power - Parts Details
Alternative NSN: 5950001035117 |
Item Name: Transformer Power |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5950 Coils and Transformers |
NIIN: 001035117 |
NCB Code: USA (00) |
Manufacturers: Freed Transformer Company , Rockwell Collins Inc , Adc Telecommunications Inc |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers 674-0114-010, 3-19974 under NSN 5950-00-103-5117 of Transformer Power manufactured by Freed Transformer Company, Rockwell Collins Inc, Adc Telecommunications Inc.
Federal Supply Class of NSN 5950-00-103-5117 is FSC 5950 contains part details of Coils and Transformers. Quote for your desired part numbers.
Part Number's List for NSN 5950-00-103-5117, 5950001035117
-
Part No Manufacturer Item Name QTY RFQ 674-0114-010 Freed Transformer Company transformer power Avl RFQ 674-0114-010 Rockwell Collins Inc transformer power Avl RFQ 3-19974 Adc Telecommunications Inc transformer power Avl RFQ
Characteristics Data of NSN 5950001035117MRC Criteria Characteristic AARG RELIABILITY INDICATOR NOT ESTABLISHED ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.813 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP ABTD MOUNTING SLOT WIDTH 0.219 INCHES NOMINAL SINGLE GROUP ACZB FREQUENCY RATING 380.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT ACZC INPUT-OUTPUT PHASE RELATIONSHIP THREE PHASE TO SINGLE PHASE SINGLE COMPONENT ACZD III TRANSFORMER WINDING CONNECTION TYPE WYE-WYE OR DELTA-WYE ADAQ BODY LENGTH 2.750 INCHES MAXIMUM ADAT BODY WIDTH 2.094 INCHES MAXIMUM ADAU BODY HEIGHT 2.406 INCHES MAXIMUM AKNA INCLOSURE TYPE FULLY INCLOSED AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP AXGY MOUNTING METHOD FLANGE SINGLE GROUP AND SLOT SINGLE GROUP BPLC WINDING FUNCTION AND QUANTITY 3 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT CRBZ WINDING OPERATING CURRENT 1.5 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY CRBZ WINDING OPERATING CURRENT 2.5 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY CWJS WINDING OPERATING VOLTAGE 11.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY CWJS WINDING OPERATING VOLTAGE 115.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY CWJS WINDING OPERATING VOLTAGE 14.00 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY TTQY TERMINAL TYPE AND QUANTITY 12 TAB, SOLDER LUG
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.813 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTD | MOUNTING SLOT WIDTH | 0.219 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 380.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZD | III TRANSFORMER WINDING CONNECTION TYPE | WYE-WYE OR DELTA-WYE |
ADAQ | BODY LENGTH | 2.750 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.094 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 2.406 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND SLOT SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 3 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 1.5 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 2.5 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 11.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 14.00 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 12 TAB, SOLDER LUG |