NSN 5950-00-409-3884 of Transformer Power - Parts Details
Alternative NSN: 5950004093884 |
Item Name: Transformer Power |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5950 Coils and Transformers |
NIIN: 004093884 |
NCB Code: USA (00) |
Manufacturers: Trane Us Inc , Quality Transformer And Electronics |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers TRR46, TRR00046, TRR-125, 39K14, 2850 under NSN 5950-00-409-3884 of Transformer Power manufactured by Trane Us Inc, Quality Transformer And Electronics.
Federal Supply Class of NSN 5950-00-409-3884 is FSC 5950 contains part details of Coils and Transformers. Quote for your desired part numbers.
Part Number's List for NSN 5950-00-409-3884, 5950004093884
-
Part No Manufacturer Item Name QTY RFQ TRR46 Trane Us Inc transformer power Avl RFQ TRR00046 Trane Us Inc transformer power Avl RFQ TRR-125 Trane Us Inc transformer power Avl RFQ 39K14 Quality Transformer And Electronics transformer power Avl RFQ 2850 Quality Transformer And Electronics transformer power Avl RFQ 13080114 Trane Us Inc transformer power Avl RFQ
Characteristics Data of NSN 5950004093884MRC Criteria Characteristic AARG RELIABILITY INDICATOR NOT ESTABLISHED ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 3.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP ABTD MOUNTING SLOT WIDTH 0.188 INCHES NOMINAL SINGLE GROUP ACZB FREQUENCY RATING 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 60.0 HERTZ MAXIMUM SINGLE COMPONENT ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT ADAQ BODY LENGTH 3.750 INCHES NOMINAL ADAT BODY WIDTH 3.250 INCHES NOMINAL ADAU BODY HEIGHT 3.438 INCHES NOMINAL AKNA INCLOSURE TYPE OPEN AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP AXGY MOUNTING METHOD FLANGE SINGLE GROUP AND SLOT SINGLE GROUP BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT CRMJ WINDING POWER RATING 150.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY CWJS WINDING OPERATING VOLTAGE 24.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY CWJS WINDING OPERATING VOLTAGE 440.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY TTQY TERMINAL TYPE AND QUANTITY 4 WIRE LEAD
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTD | MOUNTING SLOT WIDTH | 0.188 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 60.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.750 INCHES NOMINAL |
ADAT | BODY WIDTH | 3.250 INCHES NOMINAL |
ADAU | BODY HEIGHT | 3.438 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | OPEN |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND SLOT SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CRMJ | WINDING POWER RATING | 150.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 24.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 440.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
TTQY | TERMINAL TYPE AND QUANTITY | 4 WIRE LEAD |