NSN 5950-00-679-0876 of Transformer Power - Parts Details
Alternative NSN: 5950006790876 |
Item Name: Transformer Power |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5950 Coils and Transformers |
NIIN: 006790876 |
NCB Code: USA (00) |
Manufacturers: Raytheon Aircraft , Raytheon Technical Services Company , Autodyne Mfg Co Inc , Freed Transformer Company |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers RYG 9167050, A7358, 9167050 under NSN 5950-00-679-0876 of Transformer Power manufactured by Raytheon Aircraft, Raytheon Technical Services Company, Autodyne Mfg Co Inc, Freed Transformer Company.
Federal Supply Class of NSN 5950-00-679-0876 is FSC 5950 contains part details of Coils and Transformers. Quote for your desired part numbers.
Part Number's List for NSN 5950-00-679-0876, 5950006790876
-
Part No Manufacturer Item Name QTY RFQ RYG 9167050 Raytheon Aircraft transformer power Avl RFQ RYG 9167050 Raytheon Technical Services Company transformer power Avl RFQ A7358 Autodyne Mfg Co Inc transformer power Avl RFQ 9167050 Freed Transformer Company transformer power Avl RFQ
Characteristics Data of NSN 5950006790876MRC Criteria Characteristic AARG RELIABILITY INDICATOR NOT ESTABLISHED ABHP OVERALL LENGTH 6.625 INCHES NOMINAL ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 5.734 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 5.766 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 3.484 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.516 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP ABKW OVERALL HEIGHT 7.062 INCHES NOMINAL ABMK OVERALL WIDTH 6.562 INCHES NOMINAL ABTB MOUNTING HOLE DIAMETER 0.296 INCHES MINIMUM SINGLE GROUP AND 0.328 INCHES MAXIMUM SINGLE GROUP ACZB FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT ACZX WINDING SHIELDING METHOD INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT AKNA INCLOSURE TYPE HERMETICALLY SEALED AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP AXGY MOUNTING METHOD FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT CRBZ WINDING OPERATING CURRENT 10.0 AMPERES AC MAXIMUM SINGLE COMPONENT ALL SECONDARY CWJS WINDING OPERATING VOLTAGE 115.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY CWJS WINDING OPERATING VOLTAGE 119.00 AC VOLTS MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 123.50 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY CWJS WINDING OPERATING VOLTAGE 416.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY TTQY TERMINAL TYPE AND QUANTITY 7 THREADED HOLE
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 6.625 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.734 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 5.766 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.484 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.516 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 7.062 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 6.562 INCHES NOMINAL |
ABTB | MOUNTING HOLE DIAMETER | 0.296 INCHES MINIMUM SINGLE GROUP AND 0.328 INCHES MAXIMUM SINGLE GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 10.0 AMPERES AC MAXIMUM SINGLE COMPONENT ALL SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 119.00 AC VOLTS MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 123.50 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 416.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
TTQY | TERMINAL TYPE AND QUANTITY | 7 THREADED HOLE |