NSN 5950-00-704-3732 of Transformer Power - Parts Details
Alternative NSN: 5950007043732 |
Item Name: Transformer Power |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5950 Coils and Transformers |
NIIN: 007043732 |
NCB Code: USA (00) |
Manufacturers: Freed Transformer Company , Navair Ltd |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers 58A1D261, 58A15D261 under NSN 5950-00-704-3732 of Transformer Power manufactured by Freed Transformer Company, Navair Ltd.
Federal Supply Class of NSN 5950-00-704-3732 is FSC 5950 contains part details of Coils and Transformers. Quote for your desired part numbers.
Part Number's List for NSN 5950-00-704-3732, 5950007043732
Characteristics Data of NSN 5950007043732MRC Criteria Characteristic AARG RELIABILITY INDICATOR NOT ESTABLISHED ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 0.969 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP ACZB FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT ADAQ BODY LENGTH 1.938 INCHES NOMINAL ADAT BODY WIDTH 1.781 INCHES NOMINAL ADAU BODY HEIGHT 1.188 INCHES NOMINAL AEHZ MAXIMUM OPERATING TEMP 75.0 DEG CELSIUS AKNA INCLOSURE TYPE FULLY INCLOSED AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT CMLP THREAD QUANTITY PER INCH 40 SINGLE GROUP CRBZ WINDING OPERATING CURRENT 11.0 MILLIAMPERES AC MINIMUM SINGLE COMPONENT SINGLE SECONDARY CWJS WINDING OPERATING VOLTAGE 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY THSD THREAD SERIES DESIGNATOR UNC SINGLE GROUP TTQY TERMINAL TYPE AND QUANTITY 5 WIRE LEAD ACZF MAXIMUM TRANSFORMER POWER RATING 11.0 DECIBELS SINGLE COMPONENT AXGY MOUNTING METHOD THREADED HOLE SINGLE GROUP CQJX NOMINAL THREAD SIZE 0.112 INCHES SINGLE GROUP CWJS WINDING OPERATING VOLTAGE 475.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.969 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 1.938 INCHES NOMINAL |
ADAT | BODY WIDTH | 1.781 INCHES NOMINAL |
ADAU | BODY HEIGHT | 1.188 INCHES NOMINAL |
AEHZ | MAXIMUM OPERATING TEMP | 75.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CMLP | THREAD QUANTITY PER INCH | 40 SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 11.0 MILLIAMPERES AC MINIMUM SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 5 WIRE LEAD |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 11.0 DECIBELS SINGLE COMPONENT |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 475.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |