NSN 5950-00-841-4704 of Transformer Power - Parts Details
Alternative NSN: 5950008414704 |
Item Name: Transformer Power |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5950 Coils and Transformers |
NIIN: 008414704 |
NCB Code: USA (00) |
Manufacturers: Genrad Inc , Technipower Llc |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers M5S15 under NSN 5950-00-841-4704 of Transformer Power manufactured by Genrad Inc, Technipower Llc.
Federal Supply Class of NSN 5950-00-841-4704 is FSC 5950 contains part details of Coils and Transformers. Quote for your desired part numbers.
Part Number's List for NSN 5950-00-841-4704, 5950008414704
Characteristics Data of NSN 5950008414704MRC Criteria Characteristic AARG RELIABILITY INDICATOR NOT ESTABLISHED ABHP OVERALL LENGTH 3.375 INCHES NOMINAL ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 3.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 3.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP ABTB MOUNTING HOLE DIAMETER 0.265 INCHES NOMINAL SINGLE GROUP ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT ADAT BODY WIDTH 4.938 INCHES NOMINAL ADAU BODY HEIGHT 4.500 INCHES NOMINAL AKNA INCLOSURE TYPE FULLY INCLOSED AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP AXGY MOUNTING METHOD FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP CRBZ WINDING OPERATING CURRENT 5.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY CRMJ WINDING POWER RATING 860.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY CWJS WINDING OPERATING VOLTAGE 0.00 AC VOLTS MINIMUM SINGLE COMPONENT SINGLE SECONDARY AND 140.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE SECONDARY TTQY TERMINAL TYPE AND QUANTITY 5 THREADED STUD ACZB FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT ADAQ BODY LENGTH 2.500 INCHES NOMINAL BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT CWJS WINDING OPERATING VOLTAGE 20.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 3.375 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.265 INCHES NOMINAL SINGLE GROUP |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAT | BODY WIDTH | 4.938 INCHES NOMINAL |
ADAU | BODY HEIGHT | 4.500 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 5.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
CRMJ | WINDING POWER RATING | 860.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 0.00 AC VOLTS MINIMUM SINGLE COMPONENT SINGLE SECONDARY AND 140.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 5 THREADED STUD |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 2.500 INCHES NOMINAL |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 20.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |