NSN 5950-01-321-7292 of Transformer Power - Parts Details
Alternative NSN: 5950013217292 |
Item Name: Transformer Power |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5950 Coils and Transformers |
NIIN: 013217292 |
NCB Code: USA (01) |
Manufacturers: Abbott Technologies Inc |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers M27-315-05 under NSN 5950-01-321-7292 of Transformer Power manufactured by Abbott Technologies Inc.
Federal Supply Class of NSN 5950-01-321-7292 is FSC 5950 contains part details of Coils and Transformers. Quote for your desired part numbers.
Part Number's List for NSN 5950-01-321-7292, 5950013217292
-
Part No Manufacturer Item Name QTY RFQ M27-315-05 Abbott Technologies Inc transformer power Avl RFQ
Characteristics Data of NSN 5950013217292MRC Criteria Characteristic AARG RELIABILITY INDICATOR NOT ESTABLISHED ABHP OVERALL LENGTH 2.349 INCHES MINIMUM AND 2.411 INCHES MAXIMUM ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.484 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.516 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP ABMK OVERALL WIDTH 1.969 INCHES MINIMUM AND 2.031 INCHES MAXIMUM ACZB FREQUENCY RATING 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 60.0 HERTZ MAXIMUM SINGLE COMPONENT ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT ACZF MAXIMUM TRANSFORMER POWER RATING 20.0 VOLT-AMPERE SINGLE COMPONENT AEHZ MAXIMUM OPERATING TEMP 130.0 DEG CELSIUS AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP AXGY MOUNTING METHOD THREADED STUD SINGLE GROUP BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT CQJX NOMINAL THREAD SIZE 0.164 INCHES SINGLE GROUP CWJS WINDING OPERATING VOLTAGE 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY CWJS WINDING OPERATING VOLTAGE 12.60 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY TEST TEST DATA DOCUMENT 81349-MIL-T-27 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING THSD THREAD SERIES DESIGNATOR UNC SINGLE GROUP TTQY TERMINAL TYPE AND QUANTITY 5 WIRE HOOK ZZZK SPECIFICATION/STANDARD DATA 81349-MIL-T-27/315 GOVERNMENT SPECIFICATION ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.734 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.766 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP CRBZ WINDING OPERATING CURRENT 1.59 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY ABKW OVERALL HEIGHT 3.379 INCHES MINIMUM AND 3.631 INCHES MAXIMUM AKNA INCLOSURE TYPE HERMETICALLY SEALED
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 2.349 INCHES MINIMUM AND 2.411 INCHES MAXIMUM |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.484 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.516 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABMK | OVERALL WIDTH | 1.969 INCHES MINIMUM AND 2.031 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 60.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 20.0 VOLT-AMPERE SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 12.60 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
TEST | TEST DATA DOCUMENT | 81349-MIL-T-27 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 5 WIRE HOOK |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-T-27/315 GOVERNMENT SPECIFICATION |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.734 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.766 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.59 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
ABKW | OVERALL HEIGHT | 3.379 INCHES MINIMUM AND 3.631 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |