NSN 5950-01-336-0229 of Transformer Pulse - Parts Details
Alternative NSN: 5950013360229 |
Item Name: Transformer Pulse |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5950 Coils and Transformers |
NIIN: 013360229 |
NCB Code: USA (01) |
Manufacturers: Magnetika Inc , Wems Electronics Transformer Gro , Litton Systems Inc , Rayco Electronic Mfg Inc , Robert M Hadley Company Inc |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers WE4151, 841327-0001, 5T395, 19332 under NSN 5950-01-336-0229 of Transformer Pulse manufactured by Magnetika Inc, Wems Electronics Transformer Gro, Litton Systems Inc, Rayco Electronic Mfg Inc, Robert M Hadley Company Inc.
Federal Supply Class of NSN 5950-01-336-0229 is FSC 5950 contains part details of Coils and Transformers. Quote for your desired part numbers.
Part Number's List for NSN 5950-01-336-0229, 5950013360229
-
Part No Manufacturer Item Name QTY RFQ WE4151 Magnetika Inc transformer pulse Avl RFQ WE4151 Wems Electronics Transformer Gro transformer pulse Avl RFQ 841327-0001 Litton Systems Inc transformer pulse Avl RFQ 5T395 Rayco Electronic Mfg Inc transformer pulse Avl RFQ 19332 Robert M Hadley Company Inc transformer pulse Avl RFQ
Characteristics Data of NSN 5950013360229MRC Criteria Characteristic AARG RELIABILITY INDICATOR NOT ESTABLISHED ABHP OVERALL LENGTH 2.100 INCHES MAXIMUM ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.600 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP ABKW OVERALL HEIGHT 1.870 INCHES MAXIMUM ABMK OVERALL WIDTH 2.000 INCHES MAXIMUM AEHZ MAXIMUM OPERATING TEMP 85.0 DEG CELSIUS AKNA INCLOSURE TYPE FULLY INCLOSED AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP AXGY MOUNTING METHOD THREADED HOLE SINGLE GROUP BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT CQJX NOMINAL THREAD SIZE 0.138 INCHES SINGLE GROUP CRBZ WINDING OPERATING CURRENT 0.24 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY CRBZ WINDING OPERATING CURRENT 10.0 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY CRGS DC RESISTANCE RATING IN OHMS 0.005 SINGLE COMPONENT 1ST SECONDARY CRGS DC RESISTANCE RATING IN OHMS 0.300 SINGLE COMPONENT 2ND SECONDARY CRGS DC RESISTANCE RATING IN OHMS 30.000 SINGLE COMPONENT SINGLE PRIMARY CWJS WINDING OPERATING VOLTAGE 197.96 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY CWJS WINDING OPERATING VOLTAGE 36.27 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY TTQY TERMINAL TYPE AND QUANTITY 8 TURRET ABFE HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION SALT SPRAY RESISTANT AND VIBRATION RESISTANT ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.700 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP ACZB FREQUENCY RATING 33.0 KILOHERTZ NOMINAL SINGLE COMPONENT CWJS WINDING OPERATING VOLTAGE 19.80 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY TEST TEST DATA DOCUMENT 13973-841327 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI THSD THREAD SERIES DESIGNATOR UNC SINGLE GROUP
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 2.100 INCHES MAXIMUM |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.600 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 1.870 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 2.000 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 85.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 0.24 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 10.0 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.005 SINGLE COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.300 SINGLE COMPONENT 2ND SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 30.000 SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 197.96 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 36.27 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 8 TURRET |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | SALT SPRAY RESISTANT AND VIBRATION RESISTANT |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.700 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 33.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 19.80 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
TEST | TEST DATA DOCUMENT | 13973-841327 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |