NSN 6130-01-160-5345 of Power Supply - Parts Details
Alternative NSN: 6130011605345 |
Item Name: Power Supply |
FSG: 61 Electric Wire and Power and Distribution Equipment |
Federal Supply Class (FSC): 6130 Converters Electrical Non Rotating |
NIIN: 011605345 |
NCB Code: USA (01) |
Manufacturers: Paeaeesikunta Logistiikkaosasto , Texas Instrument Inc , Arnold Magnetics Corporation |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers 457-6155, 807240-1, TL-303 under NSN 6130-01-160-5345 of Power Supply manufactured by Paeaeesikunta Logistiikkaosasto, Texas Instrument Inc, Arnold Magnetics Corporation.
Federal Supply Class of NSN 6130-01-160-5345 is FSC 6130 contains part details of Converters Electrical Non Rotating. Quote for your desired part numbers.
Part Number's List for NSN 6130-01-160-5345, 6130011605345
Characteristics Data of NSN 6130011605345MRC Criteria Characteristic ABHP OVERALL LENGTH 7.000 INCHES NOMINAL ABKW OVERALL HEIGHT 4.063 INCHES NOMINAL ABMK OVERALL WIDTH 1.625 INCHES NOMINAL ADZC ENVIRONMENTAL PROTECTION HERMETICALLY SEALED AKAE MAXIMUM OPERATING ALTITUDE RATING 70000.0 FEET ANPM INPUT PHASE SINGLE SINGLE OPERATING POWER RQMT APNX INPUT VOLTAGE RATING 105.0 AC VOLTS MINIMUM SINGLE OPERATING POWER RQMT AND 125.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT APPA OUTPUT VOLTAGE RATING -15.0 DC VOLTS NOMINAL 3RD POWER OUTPUT APPA OUTPUT VOLTAGE RATING 15.0 DC VOLTS NOMINAL 1ST POWER OUTPUT APPA OUTPUT VOLTAGE RATING 5.0 DC VOLTS NOMINAL 2ND POWER OUTPUT APTQ INPUT FREQUENCY RATING 47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 500.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT AYNH OPERATING AMBIENT TEMP RANGE -10.0/+71.0 DEG CELSIUS BGHX OUTPUT CONTROL QUANTITY 1 1ST POWER OUTPUT BGHX OUTPUT CONTROL QUANTITY 1 2ND POWER OUTPUT BGHX OUTPUT CONTROL QUANTITY 1 3RD POWER OUTPUT BHQN RECTIFICATION METHOD SINGLE PHASE FULL WAVE CENTER TAP CBBL FEATURES PROVIDED FILTER CWGH OUTPUT CURRENT RATING 1.0 DC AMPERES NOMINAL 1ST POWER OUTPUT CWGH OUTPUT CURRENT RATING 1.0 DC AMPERES NOMINAL 3RD POWER OUTPUT CWGH OUTPUT CURRENT RATING 4.0 DC AMPERES NOMINAL 2ND POWER OUTPUT CWHF OUTPUT CONNECTION QUANTITY 3 1ST POWER OUTPUT CWHF OUTPUT CONNECTION QUANTITY 3 2ND POWER OUTPUT CWHF OUTPUT CONNECTION QUANTITY 3 3RD POWER OUTPUT
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 7.000 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 4.063 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.625 INCHES NOMINAL |
ADZC | ENVIRONMENTAL PROTECTION | HERMETICALLY SEALED |
AKAE | MAXIMUM OPERATING ALTITUDE RATING | 70000.0 FEET |
ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 105.0 AC VOLTS MINIMUM SINGLE OPERATING POWER RQMT AND 125.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | -15.0 DC VOLTS NOMINAL 3RD POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 15.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 5.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 500.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | -10.0/+71.0 DEG CELSIUS |
BGHX | OUTPUT CONTROL QUANTITY | 1 1ST POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 1 2ND POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 1 3RD POWER OUTPUT |
BHQN | RECTIFICATION METHOD | SINGLE PHASE FULL WAVE CENTER TAP |
CBBL | FEATURES PROVIDED | FILTER |
CWGH | OUTPUT CURRENT RATING | 1.0 DC AMPERES NOMINAL 1ST POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 1.0 DC AMPERES NOMINAL 3RD POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 4.0 DC AMPERES NOMINAL 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 3 1ST POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 3 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 3 3RD POWER OUTPUT |