Part No. : A11539 | Manufacturer : Adc Telecommunications Inc | NSN : 5950-00-252-0867 |
Item Name : Transformer Power | CAGE Code : 00144 | FSC : 5950 Coils and Transformers |
ASAP Aviation Procurement is pleased to announce that part number A11539 of NSN 5950002520867 is now available and in stock. We can get you one of the fastest and most competitive quotes on this part. Part number A11539 is a transformer power manufactured by adc telecommunications inc under CAGE Code 00144. Simply fill out the Request for Quote (RFQ) form provided here to get started on your quote.In order to make sure that we get you your quote in a timely manner, please take the time to make sure that all fields are completely filled out, particularly the asterisk-marked (*) fields like Parts Needed By and Quantity (ea).
We will be using your response to these fields to calculate your quote. Within 15 minutes of receiving your RFQ, a member of our sales team will contact you with your quote. ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is a leading distributor of new and obsolete NSN parts for the aerospace, civil aviation, and defense industries. With our inventory of more than 2 billion parts sourced from over 5000 manufacturers from around the world, we do our level best to become your go-to one-stop shop. And to help us offer you the best streamlined parts procurement experience, we have advanced shipping facilities across USA. A11539 adc telecommunications inc is in stock.
Are you interested in learning more about part number A11539? If so, feel free to contact us by phone at +1-714-705-4780, or by email at sales@asap-aviationprocurement.com. And if you are interested in an even faster and more convenient purchasing platform, check out the ASAP Semiconductor App from Google Play or the App Store.
NSN Information for Part Number A11539 with NSN 5950-00-252-0867, 5950002520867
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-252-0867 Item Description: Transformer Power | 5950 | 002520867 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
A11539 | 6 | 9 | 5 |
Characteristics Data of NSN 5950-00-252-0867, 5950002520867MRC Criteria Characteristic AARG RELIABILITY INDICATOR NOT ESTABLISHED ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.287 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.307 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.849 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.869 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP ACZB FREQUENCY RATING 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT ACZX WINDING SHIELDING METHOD INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT ADAQ BODY LENGTH 3.063 INCHES MAXIMUM ADAT BODY WIDTH 2.844 INCHES MAXIMUM ADAU BODY HEIGHT 3.740 INCHES MINIMUM AND 3.760 INCHES MAXIMUM AEHZ MAXIMUM OPERATING TEMP 105.0 DEG CELSIUS AKNA INCLOSURE TYPE HERMETICALLY SEALED AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP AXGY MOUNTING METHOD THREADED STUD SINGLE GROUP BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT CQJX NOMINAL THREAD SIZE 0.164 INCHES SINGLE GROUP CRBZ WINDING OPERATING CURRENT 3.1 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY CRBZ WINDING OPERATING CURRENT 40.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY CRBZ WINDING OPERATING CURRENT 65.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY CRTL CRITICALITY CODE JUSTIFICATION FEAT CWJS WINDING OPERATING VOLTAGE 220.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY570.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY CWJS WINDING OPERATING VOLTAGE 220.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY6.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY CWJS WINDING OPERATING VOLTAGE 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY CWJS WINDING OPERATING VOLTAGE 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY570.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY220.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY FEAT SPECIAL FEATURES ITEM IS USED ON COMMUNICATIONS RADIO SYSTEM THSD THREAD SERIES DESIGNATOR UNC SINGLE GROUP TTQY TERMINAL TYPE AND QUANTITY 10 TAB, SOLDER LUG
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.287 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.307 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.849 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.869 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.063 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.844 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 3.740 INCHES MINIMUM AND 3.760 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 105.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 3.1 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 40.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 65.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CWJS | WINDING OPERATING VOLTAGE | 220.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY570.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 220.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY6.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY570.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY220.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
FEAT | SPECIAL FEATURES | ITEM IS USED ON COMMUNICATIONS RADIO SYSTEM |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 10 TAB, SOLDER LUG |