73C828-003 by Ail Systems Inc with NSN 5950009450652 - Submit a Quote
Part No. : 73C828-003 | Alternate P/N: 73C828003 | Manufacturer : Ail Systems Inc | NSN : 5950-00-945-0652 |
Item Name : Transformer Power | CAGE Code : 04660 | FSC : 5950 Coils and Transformers |
ASAP Aviation Procurement is pleased to announce that part number 73C828-003 of NSN 5950009450652 is now available and in stock. We can get you one of the fastest and most competitive quotes on this part. Part number 73C828-003 is a transformer power manufactured by ail systems inc under CAGE Code 04660. Simply fill out the Request for Quote (RFQ) form provided here to get started on your quote.In order to make sure that we get you your quote in a timely manner, please take the time to make sure that all fields are completely filled out, particularly the asterisk-marked (*) fields like Parts Needed By and Quantity (ea).
We will be using your response to these fields to calculate your quote. Within 15 minutes of receiving your RFQ, a member of our sales team will contact you with your quote. ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is a leading distributor of new and obsolete NSN parts for the aerospace, civil aviation, and defense industries. With our inventory of more than 2 billion parts sourced from over 5000 manufacturers from around the world, we do our level best to become your go-to one-stop shop. And to help us offer you the best streamlined parts procurement experience, we have advanced shipping facilities across USA. 73C828-003 ail systems inc is in stock.
Are you interested in learning more about part number 73C828-003? If so, feel free to contact us by phone at +1-714-705-4780, or by email at sales@asap-aviationprocurement.com. And if you are interested in an even faster and more convenient purchasing platform, check out the ASAP Semiconductor App from Google Play or the App Store.
NSN Information for Part Number 73C828-003 with NSN 5950-00-945-0652, 5950009450652
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-945-0652 Item Description: Transformer Power | 5950 | 009450652 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
73c828-003 | 6 | 9 | 3 |
Characteristics Data of NSN 5950-00-945-0652, 5950009450652MRC Criteria Characteristic AARG RELIABILITY INDICATOR NOT ESTABLISHED ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.552 INCHES MINIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP AND 1.572 INCHES MAXIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 3.109 INCHES MINIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP AND 3.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 3.109 INCHES MINIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP AND 3.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 0.990 INCHES MINIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP AND 1.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.672 INCHES MINIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP AND 1.704 INCHES MAXIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.672 INCHES MINIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP AND 1.704 INCHES MAXIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP ABKW OVERALL HEIGHT 1.859 INCHES MINIMUM AND 1.891 INCHES MAXIMUM ACZB FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT ACZC INPUT-OUTPUT PHASE RELATIONSHIP THREE PHASE TO SINGLE PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENT ACZD TRANSFORMER WINDING CONNECTION TYPE WYE-DELTA ACZX WINDING SHIELDING METHOD INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT ADAQ BODY LENGTH 3.859 INCHES MINIMUM AND 3.891 INCHES MAXIMUM ADAT BODY WIDTH 2.172 INCHES MINIMUM AND 2.204 INCHES MAXIMUM AEHZ MAXIMUM OPERATING TEMP 170.0 DEG CELSIUS AEJN DISTANCE BETWEEN MOUNTING FACILITY CENTERS 1.109 INCHES MINIMUM SINGLE MOUNTING FACILITY 1ST CENTER GROUP AND 1.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY 1ST CENTER GROUP AKNA INCLOSURE TYPE FULLY INCLOSED AKPV MOUNTING FACILITY QUANTITY 2 1ST GROUP AKPV MOUNTING FACILITY QUANTITY 4 2ND GROUP AKPV MOUNTING FACILITY QUANTITY 4 3RD GROUP AKPV MOUNTING FACILITY QUANTITY 4 4TH GROUP AXGY MOUNTING METHOD THREADED HOLE ALL GROUPINGS BPLC WINDING FUNCTION AND QUANTITY 2 PRIMARY SINGLE COMPONENT AND 6 SECONDARY SINGLE COMPONENT CQJX NOMINAL THREAD SIZE 0.112 INCHES 2ND GROUP CQJX NOMINAL THREAD SIZE 0.112 INCHES 3RD GROUP CQJX NOMINAL THREAD SIZE 0.138 INCHES 1ST GROUP CQJX NOMINAL THREAD SIZE 0.164 INCHES 4TH GROUP CRBZ WINDING OPERATING CURRENT 40.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY CRBZ WINDING OPERATING CURRENT 40.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY CRBZ WINDING OPERATING CURRENT 600.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY CRBZ WINDING OPERATING CURRENT 84.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY CRMJ WINDING POWER RATING 1.6 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY CRMJ WINDING POWER RATING 1.8 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY CRMJ WINDING POWER RATING 13.86 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY CRMJ WINDING POWER RATING 5.46 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY CWJS WINDING OPERATING VOLTAGE 3.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY CWJS WINDING OPERATING VOLTAGE 346.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY CWJS WINDING OPERATING VOLTAGE 40.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY CWJS WINDING OPERATING VOLTAGE 41.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY CWJS WINDING OPERATING VOLTAGE 65.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY CWJS WINDING OPERATING VOLTAGE 8.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY FEAT SPECIAL FEATURES TWO PRIMARY WINDINGS; SIX SECONDARY WINDINGS TEST TEST DATA DOCUMENT 04660-73C828 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI THSD THREAD SERIES DESIGNATOR UNC ALL GROUPINGS TTQY TERMINAL TYPE AND QUANTITY 25 TURRET
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.552 INCHES MINIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP AND 1.572 INCHES MAXIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.109 INCHES MINIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP AND 3.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.109 INCHES MINIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP AND 3.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.990 INCHES MINIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP AND 1.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.672 INCHES MINIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP AND 1.704 INCHES MAXIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.672 INCHES MINIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP AND 1.704 INCHES MAXIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP |
ABKW | OVERALL HEIGHT | 1.859 INCHES MINIMUM AND 1.891 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SINGLE PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-DELTA |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.859 INCHES MINIMUM AND 3.891 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.172 INCHES MINIMUM AND 2.204 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 170.0 DEG CELSIUS |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.109 INCHES MINIMUM SINGLE MOUNTING FACILITY 1ST CENTER GROUP AND 1.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY 1ST CENTER GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 2 1ST GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 2ND GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 3RD GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 4TH GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE ALL GROUPINGS |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 6 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES 2ND GROUP |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES 3RD GROUP |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES 1ST GROUP |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES 4TH GROUP |
CRBZ | WINDING OPERATING CURRENT | 40.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 40.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 600.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 84.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 1.6 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
CRMJ | WINDING POWER RATING | 1.8 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 13.86 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 5.46 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 3.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 346.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 40.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 41.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 65.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 8.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY |
FEAT | SPECIAL FEATURES | TWO PRIMARY WINDINGS; SIX SECONDARY WINDINGS |
TEST | TEST DATA DOCUMENT | 04660-73C828 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI |
THSD | THREAD SERIES DESIGNATOR | UNC ALL GROUPINGS |
TTQY | TERMINAL TYPE AND QUANTITY | 25 TURRET |
Related NSN Components For 73C828-003
Part 73C828-003 With Different Manufacturers
Industry's fastest RFQ turnaround. Get the answers you need now.
E-mail us at
sales@asap-aviationprocurement.com