27-0050-10 by Hisonic Inc with NSN 5950013614341 - Submit a Quote
Part No. : 27-0050-10 | Alternate P/N: 27005010 | Manufacturer : Hisonic Inc | NSN : 5950-01-361-4341 |
Item Name : Reactor Transformer | CAGE Code : 11402 | FSC : 5950 Coils and Transformers |
ASAP Aviation Procurement is pleased to announce that part number 27-0050-10 of NSN 5950013614341 is now available and in stock. We can get you one of the fastest and most competitive quotes on this part. Part number 27-0050-10 is a reactor transformer manufactured by hisonic inc under CAGE Code 11402. Simply fill out the Request for Quote (RFQ) form provided here to get started on your quote.In order to make sure that we get you your quote in a timely manner, please take the time to make sure that all fields are completely filled out, particularly the asterisk-marked (*) fields like Parts Needed By and Quantity (ea).
We will be using your response to these fields to calculate your quote. Within 15 minutes of receiving your RFQ, a member of our sales team will contact you with your quote. ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is a leading distributor of new and obsolete NSN parts for the aerospace, civil aviation, and defense industries. With our inventory of more than 2 billion parts sourced from over 5000 manufacturers from around the world, we do our level best to become your go-to one-stop shop. And to help us offer you the best streamlined parts procurement experience, we have advanced shipping facilities across USA. 27-0050-10 hisonic inc is in stock.
Are you interested in learning more about part number 27-0050-10? If so, feel free to contact us by phone at +1-714-705-4780, or by email at sales@asap-aviationprocurement.com. And if you are interested in an even faster and more convenient purchasing platform, check out the ASAP Semiconductor App from Google Play or the App Store.
NSN Information for Part Number 27-0050-10 with NSN 5950-01-361-4341, 5950013614341
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-361-4341 Item Description: Reactor Transformer | 5950 | 013614341 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
27-0050-10 | 6 | 2 | 5 |
Characteristics Data of NSN 5950-01-361-4341, 5950013614341MRC Criteria Characteristic AARG RELIABILITY INDICATOR NOT ESTABLISHED ABHY TURN QUANTITY 50 3RD COMPONENT SINGLE WINDING ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.900 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP ABKW OVERALL HEIGHT 1.400 INCHES NOMINAL ACZB FREQUENCY RATING 10.0 KILOHERTZ NOMINAL 3RD COMPONENT ACZB FREQUENCY RATING 100.0 KILOHERTZ NOMINAL 1ST COMPONENT ACZB FREQUENCY RATING 100.0 KILOHERTZ NOMINAL 2ND COMPONENT ACZX WINDING SHIELDING METHOD INTERNAL SHIELD CONNECTED TO SECONDARY TERMINAL 1ST COMPONENT ACZX WINDING SHIELDING METHOD INTERNALLY SHIELDED AND BROUGHT OUT TO PRIMARY TERMINAL 2ND COMPONENT ADAQ BODY LENGTH 3.400 INCHES NOMINAL ADAT BODY WIDTH 2.000 INCHES NOMINAL AEHZ MAXIMUM OPERATING TEMP 55.0 DEG CELSIUS AKNA INCLOSURE TYPE FULLY INCLOSED AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP AXGY MOUNTING METHOD THREADED HOLE SINGLE GROUP BKPL RATING METHOD ELECTRICAL 3RD COMPONENT SINGLE WINDING AND WINDING TURNS 3RD COMPONENT SINGLE WINDING BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY 1ST COMPONENT AND 3 SECONDARY 1ST COMPONENT BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY 2ND COMPONENT CBBL FEATURES PROVIDED TINNED WIRE LEADS CQPZ WINDING CONDUCTOR SIZE 0.00795 INCHES AMERICAN WIRE GAGE 3RD COMPONENT SINGLE WINDING CRBZ WINDING OPERATING CURRENT 16.0 AMPERES AC NOMINAL 2ND COMPONENT SINGLE PRIMARY CRGS DC RESISTANCE RATING IN OHMS 0.150 3RD COMPONENT SINGLE WINDING CWJS WINDING OPERATING VOLTAGE 10.00 AC VOLTS NOMINAL 2ND COMPONENT SINGLE PRIMARY CWJS WINDING OPERATING VOLTAGE 7.70 AC VOLTS NOMINAL 1ST COMPONENT SINGLE PRIMARY TTQY TERMINAL TYPE AND QUANTITY 18 WIRE LEAD FEAT SPECIAL FEATURES 2ND COMPONENT,CURRENT TRANSFORMER,SECONDARY RATED BUT NOT INCLUDED ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP CQJX NOMINAL THREAD SIZE 0.112 INCHES SINGLE GROUP THSD THREAD SERIES DESIGNATOR UNC SINGLE GROUP
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHY | TURN QUANTITY | 50 3RD COMPONENT SINGLE WINDING |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.900 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 1.400 INCHES NOMINAL |
ACZB | FREQUENCY RATING | 10.0 KILOHERTZ NOMINAL 3RD COMPONENT |
ACZB | FREQUENCY RATING | 100.0 KILOHERTZ NOMINAL 1ST COMPONENT |
ACZB | FREQUENCY RATING | 100.0 KILOHERTZ NOMINAL 2ND COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD CONNECTED TO SECONDARY TERMINAL 1ST COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNALLY SHIELDED AND BROUGHT OUT TO PRIMARY TERMINAL 2ND COMPONENT |
ADAQ | BODY LENGTH | 3.400 INCHES NOMINAL |
ADAT | BODY WIDTH | 2.000 INCHES NOMINAL |
AEHZ | MAXIMUM OPERATING TEMP | 55.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BKPL | RATING METHOD | ELECTRICAL 3RD COMPONENT SINGLE WINDING AND WINDING TURNS 3RD COMPONENT SINGLE WINDING |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 1ST COMPONENT AND 3 SECONDARY 1ST COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 2ND COMPONENT |
CBBL | FEATURES PROVIDED | TINNED WIRE LEADS |
CQPZ | WINDING CONDUCTOR SIZE | 0.00795 INCHES AMERICAN WIRE GAGE 3RD COMPONENT SINGLE WINDING |
CRBZ | WINDING OPERATING CURRENT | 16.0 AMPERES AC NOMINAL 2ND COMPONENT SINGLE PRIMARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.150 3RD COMPONENT SINGLE WINDING |
CWJS | WINDING OPERATING VOLTAGE | 10.00 AC VOLTS NOMINAL 2ND COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 7.70 AC VOLTS NOMINAL 1ST COMPONENT SINGLE PRIMARY |
TTQY | TERMINAL TYPE AND QUANTITY | 18 WIRE LEAD |
FEAT | SPECIAL FEATURES | 2ND COMPONENT,CURRENT TRANSFORMER,SECONDARY RATED BUT NOT INCLUDED |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SINGLE GROUP |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |