842-014-001 by Parker Hannifin Corporation with NSN 5950004442205 - Submit a Quote
Part No. : 842-014-001 | Alternate P/N: 842014001 | Manufacturer : Parker Hannifin Corporation | NSN : 5950-00-444-2205 |
Item Name : Transformer Power | CAGE Code : 59211 | FSC : 5950 Coils and Transformers |
ASAP Aviation Procurement is pleased to announce that part number 842-014-001 of NSN 5950004442205 is now available and in stock. We can get you one of the fastest and most competitive quotes on this part. Part number 842-014-001 is a transformer power manufactured by parker hannifin corporation under CAGE Code 59211. Simply fill out the Request for Quote (RFQ) form provided here to get started on your quote.In order to make sure that we get you your quote in a timely manner, please take the time to make sure that all fields are completely filled out, particularly the asterisk-marked (*) fields like Parts Needed By and Quantity (ea).
We will be using your response to these fields to calculate your quote. Within 15 minutes of receiving your RFQ, a member of our sales team will contact you with your quote. ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is a leading distributor of new and obsolete NSN parts for the aerospace, civil aviation, and defense industries. With our inventory of more than 2 billion parts sourced from over 5000 manufacturers from around the world, we do our level best to become your go-to one-stop shop. And to help us offer you the best streamlined parts procurement experience, we have advanced shipping facilities across USA. 842-014-001 parker hannifin corporation is in stock.
Are you interested in learning more about part number 842-014-001? If so, feel free to contact us by phone at +1-714-705-4780, or by email at sales@asap-aviationprocurement.com. And if you are interested in an even faster and more convenient purchasing platform, check out the ASAP Semiconductor App from Google Play or the App Store.
NSN Information for Part Number 842-014-001 with NSN 5950-00-444-2205, 5950004442205
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-444-2205 Item Description: Transformer Power | 5950 | 004442205 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
842-014-001 | 6 | 2 | 3 |
Characteristics Data of NSN 5950-00-444-2205, 5950004442205MRC Criteria Characteristic AARG RELIABILITY INDICATOR NOT ESTABLISHEDNOT ESTABLISHED ABTB MOUNTING HOLE DIAMETER 0.098 INCHES NOMINAL SINGLE GROUP0.098 INCHES NOMINAL SINGLE GROUP ACZB FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT ADAQ BODY LENGTH 1.065 INCHES NOMINAL1.065 INCHES NOMINAL ADAT BODY WIDTH 1.063 INCHES MAXIMUM1.063 INCHES MAXIMUM ADAU BODY HEIGHT 0.795 INCHES MAXIMUM0.795 INCHES MAXIMUM AEJN DISTANCE BETWEEN MOUNTING FACILITY CENTERS 1.315 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP1.315 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AKNA INCLOSURE TYPE OPENOPEN AKPV MOUNTING FACILITY QUANTITY 2 SINGLE GROUP2 SINGLE GROUP AXGY MOUNTING METHOD FLANGE SINGLE GROUP AND FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUPUNTHREADED HOLE SINGLE GROUP BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT3 SECONDARY SINGLE COMPONENT CRBZ WINDING OPERATING CURRENT 100.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY CRBZ WINDING OPERATING CURRENT 14.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY CRBZ WINDING OPERATING CURRENT 30.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY CRBZ WINDING OPERATING CURRENT 35.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY CWJS WINDING OPERATING VOLTAGE 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY14.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY CWJS WINDING OPERATING VOLTAGE 14.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY CWJS WINDING OPERATING VOLTAGE 27.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY32.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY CWJS WINDING OPERATING VOLTAGE 32.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY TTQY TERMINAL TYPE AND QUANTITY 12 WIRE LEAD
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABTB | MOUNTING HOLE DIAMETER | 0.098 INCHES NOMINAL SINGLE GROUP0.098 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 1.065 INCHES NOMINAL1.065 INCHES NOMINAL |
ADAT | BODY WIDTH | 1.063 INCHES MAXIMUM1.063 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.795 INCHES MAXIMUM0.795 INCHES MAXIMUM |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.315 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP1.315 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AKNA | INCLOSURE TYPE | OPENOPEN |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP2 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUPUNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT3 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 100.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 14.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 30.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 35.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY14.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 14.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 27.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY32.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 32.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 12 WIRE LEAD |
Related NSN Components For 842-014-001
Part 842-014-001 With Different Manufacturers