NSN 5905-00-006-7015 of Resistor Thermal - Parts Details
Alternative NSN: 5905000067015 |
Item Name: Resistor Thermal |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5905 Resistors |
NIIN: 000067015 |
NCB Code: USA (00) |
Manufacturers: Texas Instrument Inc , Rtie Holdings Llc , Raytheon Aircraft |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers TM1-4-4700, 10-00157-048 under NSN 5905-00-006-7015 of Resistor Thermal manufactured by Texas Instrument Inc, Rtie Holdings Llc, Raytheon Aircraft.
Federal Supply Class of NSN 5905-00-006-7015 is FSC 5905 contains part details of Resistors. Quote for your desired part numbers.
Part Number's List for NSN 5905-00-006-7015, 5905000067015
-
Part No Manufacturer Item Name QTY RFQ TM1-4-4700 Texas Instrument Inc resistor thermal Avl RFQ TM1-4-4700 Rtie Holdings Llc resistor thermal Avl RFQ TM1-4-4700 Raytheon Aircraft resistor thermal Avl RFQ 10-00157-048 Raytheon Aircraft resistor thermal Avl RFQ
Characteristics Data of NSN 5905000067015MRC Criteria Characteristic AARG RELIABILITY INDICATOR NOT ESTABLISHED ABJT TERMINAL LENGTH 1.250 INCHES MINIMUM ADAQ BODY LENGTH 0.410 INCHES NOMINAL ADAR BODY OUTSIDE DIAMETER 0.140 INCHES MAXIMUM AEBT TERMINAL DIAMETER 0.025 INCHES NOMINAL AEHX MAXIMUM POWER DISSIPATION RATING 500.00 MILLIWATTS AEHY AMBIENT TEMP AT FULL RATED POWER 25.0 DEG CELSIUS AEHZ MAXIMUM OPERATING TEMP 125.0 DEG CELSIUS AEJA THERMAL TIME CONSTANT IN SECONDS 60.0 AEJB POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS 5.0 AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER -15.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER -55.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER 100.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER 125.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER 50.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER 75.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 2.4 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 3.4 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 5.8 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 6.8 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 7.9 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 9.2 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT AEJF RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT -12.0/+12.0 3RD RESISTANCE-TEMPERATURE POINT AEJF RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT -14.0 TO 14.0 2ND RESISTANCE-TEMPERATURE POINT AEJF RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT -14.0 TO 14.0 4TH RESISTANCE-TEMPERATURE POINT AEJF RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT -17.0/+17.0 5TH RESISTANCE-TEMPERATURE POINT AEJF RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT -20.0 TO 20.0 6TH RESISTANCE-TEMPERATURE POINT AEJF RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT -20.0/+20.0 1ST RESISTANCE-TEMPERATURE POINT AKNA INCLOSURE TYPE ENCAPSULATED CQWD III ZERO POWER RESISTANCE 4.700 KILOHMS CRQJ ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP -10.0/+10.0 STYL STYLE DESIGNATOR ROD TEST TEST DATA DOCUMENT 81349-MILT23648 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING TTQY TERMINAL TYPE AND QUANTITY 2 WIRE LEAD
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 1.250 INCHES MINIMUM |
ADAQ | BODY LENGTH | 0.410 INCHES NOMINAL |
ADAR | BODY OUTSIDE DIAMETER | 0.140 INCHES MAXIMUM |
AEBT | TERMINAL DIAMETER | 0.025 INCHES NOMINAL |
AEHX | MAXIMUM POWER DISSIPATION RATING | 500.00 MILLIWATTS |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 25.0 DEG CELSIUS |
AEHZ | MAXIMUM OPERATING TEMP | 125.0 DEG CELSIUS |
AEJA | THERMAL TIME CONSTANT IN SECONDS | 60.0 |
AEJB | POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 5.0 |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -15.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -55.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 2.4 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 3.4 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 5.8 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 6.8 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 7.9 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 9.2 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.0/+12.0 3RD RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -14.0 TO 14.0 2ND RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -14.0 TO 14.0 4TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -17.0/+17.0 5TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -20.0 TO 20.0 6TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -20.0/+20.0 1ST RESISTANCE-TEMPERATURE POINT |
AKNA | INCLOSURE TYPE | ENCAPSULATED |
CQWD | III ZERO POWER RESISTANCE | 4.700 KILOHMS |
CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0/+10.0 |
STYL | STYLE DESIGNATOR | ROD |
TEST | TEST DATA DOCUMENT | 81349-MILT23648 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |