NSN 5905-00-761-0026 of Resistor Network Fixed Wirewound - Parts Details
Alternative NSN: 5905007610026 |
Item Name: Resistor Network Fixed Wirewound |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5905 Resistors |
NIIN: 007610026 |
NCB Code: USA (00) |
Manufacturers: Shallcross Inc , White Consolidated Industries Inc , Tektronix Inc |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers NR687, 307-067, 307-0067-00 under NSN 5905-00-761-0026 of Resistor Network Fixed Wirewound manufactured by Shallcross Inc, White Consolidated Industries Inc, Tektronix Inc.
Federal Supply Class of NSN 5905-00-761-0026 is FSC 5905 contains part details of Resistors. Quote for your desired part numbers.
Part Number's List for NSN 5905-00-761-0026, 5905007610026
-
Part No Manufacturer Item Name QTY RFQ NR687 Shallcross Inc resistor network fixed wirewound Avl RFQ NR687 White Consolidated Industries Inc resistor network fixed wirewound Avl RFQ 307-067 Tektronix Inc resistor network fixed wirewound Avl RFQ 307-0067-00 Tektronix Inc resistor network fixed wirewound Avl RFQ
Characteristics Data of NSN 5905007610026MRC Criteria Characteristic AAPE TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS -10.0 TO 10.0 AAPP ELECTRICAL RESISTANCE 270.000 KILOHMS LOWEST RESISTANCE VALUE AAPP ELECTRICAL RESISTANCE 297.000 KILOHMS 1ST INTERMEDIATE RESISTANCE VALUE AAPP ELECTRICAL RESISTANCE 3.030 KILOHMS 2ND INTERMEDIATE RESISTANCE VALUE AAPP ELECTRICAL RESISTANCE 33.333 KILOHMS HIGHEST RESISTANCE VALUE AAPQ RESISTANCE TOLERANCE IN PERCENT -0.100 TO 0.100 EACH RESISTOR AAQH TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS +20.0 TO 85.0 AAQZ INCLOSURE METHOD ENCAPSULATED AARA TERMINAL QUANTITY 8 AARB TERMINAL TYPE TURRET AARG RELIABILITY INDICATOR NOT ESTABLISHED ABJT TERMINAL LENGTH 0.188 INCHES MINIMUM ADAQ BODY LENGTH 1.500 INCHES MAXIMUM ADAT BODY WIDTH 1.188 INCHES MAXIMUM ADAU BODY HEIGHT 0.500 INCHES MAXIMUM CQRD IDENTICAL VALUE RESISTOR QUANTITY 1 1ST INTERMEDIATE RESISTANCE VALUE CQRD IDENTICAL VALUE RESISTOR QUANTITY 1 2ND INTERMEDIATE RESISTANCE VALUE CQRD IDENTICAL VALUE RESISTOR QUANTITY 1 HIGHEST RESISTANCE VALUE CQRD IDENTICAL VALUE RESISTOR QUANTITY 1 LOWEST RESISTANCE VALUE STYL STYLE DESIGNATOR TERMINALS ONE END
MRC | Criteria | Characteristic |
---|---|---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -10.0 TO 10.0 |
AAPP | ELECTRICAL RESISTANCE | 270.000 KILOHMS LOWEST RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 297.000 KILOHMS 1ST INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 3.030 KILOHMS 2ND INTERMEDIATE RESISTANCE VALUE |
AAPP | ELECTRICAL RESISTANCE | 33.333 KILOHMS HIGHEST RESISTANCE VALUE |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -0.100 TO 0.100 EACH RESISTOR |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | +20.0 TO 85.0 |
AAQZ | INCLOSURE METHOD | ENCAPSULATED |
AARA | TERMINAL QUANTITY | 8 |
AARB | TERMINAL TYPE | TURRET |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 0.188 INCHES MINIMUM |
ADAQ | BODY LENGTH | 1.500 INCHES MAXIMUM |
ADAT | BODY WIDTH | 1.188 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.500 INCHES MAXIMUM |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 1ST INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 2ND INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 HIGHEST RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 LOWEST RESISTANCE VALUE |
STYL | STYLE DESIGNATOR | TERMINALS ONE END |