NSN 5905-01-017-0077 of Resistor Variable Wire Wound Non - Parts Details
Alternative NSN: 5905010170077 |
Item Name: Resistor Variable Wire Wound Non |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5905 Resistors |
NIIN: 010170077 |
NCB Code: USA (01) |
Manufacturers: Dla Land And Maritime , Bourns Instruments Inc , Vickers Inc |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers L01923, 3057J-1-201, 15A2113-5 under NSN 5905-01-017-0077 of Resistor Variable Wire Wound Non manufactured by Dla Land And Maritime, Bourns Instruments Inc, Vickers Inc.
Federal Supply Class of NSN 5905-01-017-0077 is FSC 5905 contains part details of Resistors. Quote for your desired part numbers.
Part Number's List for NSN 5905-01-017-0077, 5905010170077
Characteristics Data of NSN 5905010170077MRC Criteria Characteristic AAPN SECTION QUANTITY 1 AAQL BODY STYLE RECTANGULAR W/MOUNTING HOLES/SLOTS AARG RELIABILITY INDICATOR NOT ESTABLISHED ABHP III OVERALL LENGTH 1.308 INCHES NOMINAL ABKW III OVERALL HEIGHT 0.470 INCHES NOMINAL ABMK III OVERALL WIDTH 0.190 INCHES NOMINAL ABTB MOUNTING HOLE DIAMETER 0.093 INCHES NOMINAL ABWV SHAFT DIAMETER 0.115 INCHES NOMINAL ABXF SHAFT LENGTH 0.058 INCHES NOMINAL ADAQ BODY LENGTH 1.250 INCHES NOMINAL ADAT BODY WIDTH 0.190 INCHES NOMINAL ADAU BODY HEIGHT 0.320 INCHES NOMINAL AEDX SHAFT STYLE ROUND, SLOTTED AEFD ACTUATOR TYPE SINGLE SHAFT AEFH EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION 7920.0 NOMINAL AEHT CENTER TO CENTER DISTANCE BETWEEN TERMINALS 0.700 INCHES NOMINAL AGTP LATERAL DISTANCE BETWEEN MOUNTING HOLE CENTERS 1.000 INCHES NOMINAL AKPV MOUNTING FACILITY QUANTITY 2 APXH TERMINAL LOCATION LOWER ADJACENT SIDE SINGLE ROW AXGY MOUNTING METHOD UNTHREADED HOLE AND TERMINAL AYQR CENTER TO CENTER DISTANCE BETWEEN TERMINAL ROWS 0.100 INCHES NOMINAL CQCC ELECTRICAL RESISTANCE PER SECTION 200.0 OHMS SINGLE SECTION CQCM CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL 0.300 INCHES NOMINAL CQGN AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER 150.0 SINGLE SECTION CRFJ TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS -50.0 TO 50.0 SINGLE SECTION CRGD POWER DISSIPATION RATING PER SECTION IN WATTS 1.0 FREE AIR SINGLE SECTION CRSS RESISTANCE TOLERANCE PER SECTION IN PERCENT -5.0 TO 5.0 SINGLE SECTION CRTL CRITICALITY CODE JUSTIFICATION FEAT CSDH AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER 70.0 SINGLE SECTION FEAT SPECIAL FEATURES FOR NAVY NUCLEAR PROPULSION PLANT PRODUCTS ONLY,ITEM MUST COMPLY WITH REQUIREMENTS OF DEFENSE ELECTRONICS SUPPLY CENTER PRODUCTION STANDARD NO. L01923 TTQY TERMINAL TYPE AND QUANTITY 3 WIRE LOOP
MRC | Criteria | Characteristic |
---|---|---|
AAPN | SECTION QUANTITY | 1 |
AAQL | BODY STYLE | RECTANGULAR W/MOUNTING HOLES/SLOTS |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | III OVERALL LENGTH | 1.308 INCHES NOMINAL |
ABKW | III OVERALL HEIGHT | 0.470 INCHES NOMINAL |
ABMK | III OVERALL WIDTH | 0.190 INCHES NOMINAL |
ABTB | MOUNTING HOLE DIAMETER | 0.093 INCHES NOMINAL |
ABWV | SHAFT DIAMETER | 0.115 INCHES NOMINAL |
ABXF | SHAFT LENGTH | 0.058 INCHES NOMINAL |
ADAQ | BODY LENGTH | 1.250 INCHES NOMINAL |
ADAT | BODY WIDTH | 0.190 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0.320 INCHES NOMINAL |
AEDX | SHAFT STYLE | ROUND, SLOTTED |
AEFD | ACTUATOR TYPE | SINGLE SHAFT |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 7920.0 NOMINAL |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.700 INCHES NOMINAL |
AGTP | LATERAL DISTANCE BETWEEN MOUNTING HOLE CENTERS | 1.000 INCHES NOMINAL |
AKPV | MOUNTING FACILITY QUANTITY | 2 |
APXH | TERMINAL LOCATION | LOWER ADJACENT SIDE SINGLE ROW |
AXGY | MOUNTING METHOD | UNTHREADED HOLE AND TERMINAL |
AYQR | CENTER TO CENTER DISTANCE BETWEEN TERMINAL ROWS | 0.100 INCHES NOMINAL |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 200.0 OHMS SINGLE SECTION |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.300 INCHES NOMINAL |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 150.0 SINGLE SECTION |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -50.0 TO 50.0 SINGLE SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 1.0 FREE AIR SINGLE SECTION |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -5.0 TO 5.0 SINGLE SECTION |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 70.0 SINGLE SECTION |
FEAT | SPECIAL FEATURES | FOR NAVY NUCLEAR PROPULSION PLANT PRODUCTS ONLY,ITEM MUST COMPLY WITH REQUIREMENTS OF DEFENSE ELECTRONICS SUPPLY CENTER PRODUCTION STANDARD NO. L01923 |
TTQY | TERMINAL TYPE AND QUANTITY | 3 WIRE LOOP |