NSN 5905-01-115-2040 of Resistor Thermal - Parts Details
Alternative NSN: 5905011152040 |
Item Name: Resistor Thermal |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5905 Resistors |
NIIN: 011152040 |
NCB Code: USA (01) |
Manufacturers: Condor D C Power Supplies Inc , Keystone Carbon Co Inc |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers 2600001, 15-1K-139-S1 under NSN 5905-01-115-2040 of Resistor Thermal manufactured by Condor D C Power Supplies Inc, Keystone Carbon Co Inc.
Federal Supply Class of NSN 5905-01-115-2040 is FSC 5905 contains part details of Resistors. Quote for your desired part numbers.
Part Number's List for NSN 5905-01-115-2040, 5905011152040
-
Part No Manufacturer Item Name QTY RFQ 2600001 Condor D C Power Supplies Inc resistor thermal Avl RFQ 15-1K-139-S1 Keystone Carbon Co Inc resistor thermal Avl RFQ
Characteristics Data of NSN 5905011152040MRC Criteria Characteristic AARG RELIABILITY INDICATOR NOT ESTABLISHED ABJT TERMINAL LENGTH 1.500 INCHES NOMINAL ADAQ BODY LENGTH 0.515 INCHES MAXIMUM ADAR BODY OUTSIDE DIAMETER 0.210 INCHES MAXIMUM AEBT TERMINAL DIAMETER 0.031 INCHES NOMINAL AEHZ MAXIMUM OPERATING TEMP 125.0 DEG CELSIUS AEJA THERMAL TIME CONSTANT IN SECONDS 45.0 AEJB POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS 9.0 AEJC ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS 3.38 AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER 0.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER 125.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER 50.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT AEJD TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER 75.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 2.5 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 227.0 OHMS 3RD RESISTANCE-TEMPERATURE POINT AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 451.0 OHMS 2ND RESISTANCE-TEMPERATURE POINT AEJE ZERO POWER RESISTANCE AT SPECIFIED TEMP 71.9 OHMS 4TH RESISTANCE-TEMPERATURE POINT AKNA INCLOSURE TYPE ENCAPSULATED CQWD III ZERO POWER RESISTANCE 1.000 KILOHMS CRQJ ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP -10.0/+10.0 CTGT REFERENCE TEMP IN DEG CELSIUS 25.0 STYL STYLE DESIGNATOR ROD TTQY TERMINAL TYPE AND QUANTITY 2 WIRE LEAD
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 1.500 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.515 INCHES MAXIMUM |
ADAR | BODY OUTSIDE DIAMETER | 0.210 INCHES MAXIMUM |
AEBT | TERMINAL DIAMETER | 0.031 INCHES NOMINAL |
AEHZ | MAXIMUM OPERATING TEMP | 125.0 DEG CELSIUS |
AEJA | THERMAL TIME CONSTANT IN SECONDS | 45.0 |
AEJB | POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 9.0 |
AEJC | ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | 3.38 |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 2.5 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 227.0 OHMS 3RD RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 451.0 OHMS 2ND RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 71.9 OHMS 4TH RESISTANCE-TEMPERATURE POINT |
AKNA | INCLOSURE TYPE | ENCAPSULATED |
CQWD | III ZERO POWER RESISTANCE | 1.000 KILOHMS |
CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0/+10.0 |
CTGT | REFERENCE TEMP IN DEG CELSIUS | 25.0 |
STYL | STYLE DESIGNATOR | ROD |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |