NSN 5915-01-347-4082 of Filter Band Pass - Parts Details
Alternative NSN: 5915013474082 |
Item Name: Filter Band Pass |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5915 Filters and Networks |
NIIN: 013474082 |
NCB Code: USA (01) |
Manufacturers: R S Microwave Co Inc , Kl Microwave Inc , Tern Technology Inc |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers 93551-5, 7ED10-6200 T4400-0 0, 10136531-101 under NSN 5915-01-347-4082 of Filter Band Pass manufactured by R S Microwave Co Inc, Kl Microwave Inc, Tern Technology Inc.
Federal Supply Class of NSN 5915-01-347-4082 is FSC 5915 contains part details of Filters and Networks. Quote for your desired part numbers.
Part Number's List for NSN 5915-01-347-4082, 5915013474082
-
Part No Manufacturer Item Name QTY RFQ 93551-5 R S Microwave Co Inc filter band pass Avl RFQ 7ED10-6200 T4400-0 0 Kl Microwave Inc filter band pass Avl RFQ 10136531-101 Tern Technology Inc filter band pass Avl RFQ
Characteristics Data of NSN 5915013474082MRC Criteria Characteristic ABHP OVERALL LENGTH 1.570 INCHES NOMINAL ADAQ BODY LENGTH 0.810 INCHES NOMINAL ADAT BODY WIDTH 0.500 INCHES NOMINAL ADAU BODY HEIGHT 0.810 INCHES NOMINAL AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 0.612 INCHES NOMINAL AFGA OPERATING TEMP RANGE -54.0/+60.0 DEG CELSIUS AGAV END ITEM IDENTIFICATION F15 AIRCRAFT AHAJ REFERENCE FREQUENCY PER FUNCTION 6.2 GIGAHERTZ BLANK AHAQ SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS BLANK AHBZ VOLTAGE STANDING WAVE RATIO PER FUNCTION 1.5 BLANK AKEJ MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR UNC AKNA INCLOSURE TYPE ENCASED AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 THREADED HOLE CQDR INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS 0.75 BLANK CQDW FUNCTIONAL TERMINAL TYPE AND QUANTITY 1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION1 CONNECTOR, RECEPTACLE OUTPUT 2ND FUNCTION CQFC SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION 2.02 GIGAHERTZ BLANK AND 4.00 GIGAHERTZ BLANK AND 8.40 GIGAHERTZ BLANK AND 10.60 GIGAHERTZ BLANK CQJX NOMINAL THREAD SIZE 0.086 INCHES CQRG BODY MATERIAL METAL CRBC DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS 3.0 MINIMUM BLANK AND 40.0 MAXIMUM BLANK CRBN VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION 4.0 GIGAHERTZ BLANK AND 8.4 GIGAHERTZ BLANK PKWT UNPACKAGED UNIT WEIGHT 0.450 OUNCES AHAS LOAD IMPEDANCE PER FUNCTION 50.0 OHMS BLANK AEHA DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.612 INCHES NOMINAL CRBB FREQUENCY BAND WIDTH PER FUNCTION 4.00 GIGAHERTZ BLANK AND 8.40 GIGAHERTZ BLANK STYL STYLE DESIGNATOR RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 1.570 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.810 INCHES NOMINAL |
ADAT | BODY WIDTH | 0.500 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0.810 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 0.612 INCHES NOMINAL |
AFGA | OPERATING TEMP RANGE | -54.0/+60.0 DEG CELSIUS |
AGAV | END ITEM IDENTIFICATION | F15 AIRCRAFT |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 6.2 GIGAHERTZ BLANK |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS BLANK |
AHBZ | VOLTAGE STANDING WAVE RATIO PER FUNCTION | 1.5 BLANK |
AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
AKNA | INCLOSURE TYPE | ENCASED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 0.75 BLANK |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION1 CONNECTOR, RECEPTACLE OUTPUT 2ND FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 2.02 GIGAHERTZ BLANK AND 4.00 GIGAHERTZ BLANK AND 8.40 GIGAHERTZ BLANK AND 10.60 GIGAHERTZ BLANK |
CQJX | NOMINAL THREAD SIZE | 0.086 INCHES |
CQRG | BODY MATERIAL | METAL |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 3.0 MINIMUM BLANK AND 40.0 MAXIMUM BLANK |
CRBN | VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION | 4.0 GIGAHERTZ BLANK AND 8.4 GIGAHERTZ BLANK |
PKWT | UNPACKAGED UNIT WEIGHT | 0.450 OUNCES |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS BLANK |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.612 INCHES NOMINAL |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 4.00 GIGAHERTZ BLANK AND 8.40 GIGAHERTZ BLANK |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |