NSN 5925-00-248-1440 of Tripper Circuit Breaker - Parts Details
Alternative NSN: 5925002481440 |
Item Name: Tripper Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 002481440 |
NCB Code: USA (00) |
Manufacturers: Spd Electrical Systems Inc |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers ETN4237 under NSN 5925-00-248-1440 of Tripper Circuit Breaker manufactured by Spd Electrical Systems Inc.
Federal Supply Class of NSN 5925-00-248-1440 is FSC 5925 contains part details of Circuit Breakers. Quote for your desired part numbers.
Part Number's List for NSN 5925-00-248-1440, 5925002481440
Characteristics Data of NSN 5925002481440MRC Criteria Characteristic AAQL BODY STYLE RECTANGULAR DIMENSIONAL ENVELOPE ABHP OVERALL LENGTH 4.594 INCHES NOMINAL ABKW OVERALL HEIGHT 3.531 INCHES NOMINAL ABMK OVERALL WIDTH 3.844 INCHES NOMINAL AKPX III POLE QUANTITY 3 AXHR MOUNTING FACILITY TYPE AND QUANTITY 6 TERMINAL CBBL FEATURES PROVIDED ADJUSTABLE TRIP RELEASE CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 50.0 AMPERES AC ALL LOCATIONS CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 500.0 AC ALL LOCATIONS CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS CPRJ TRIP RELEASE METHOD THERMAL-MAGNETIC ALL LOCATIONS CPRL TRIP RELEASE CHARACTERISTIC INSTANTANEOUS ALL LOCATIONS AND TIME DELAY ALL LOCATIONS CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 175.0 ALL LOCATIONS CPSF ADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPS +300.0 TO 350.0 AC ALL LOCATIONS CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 420.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 1500.000 MAXIMUM AT 200 PCT ALL LOCATIONS CRCF TRIP RELEASE AMBIENT TEMP RATING 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS FREQ FREQUENCY IN HERTZ 60.0 ALL LOCATIONS TTQY TERMINAL TYPE AND QUANTITY 6 SCREW
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | RECTANGULAR DIMENSIONAL ENVELOPE |
ABHP | OVERALL LENGTH | 4.594 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 3.531 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 3.844 INCHES NOMINAL |
AKPX | III POLE QUANTITY | 3 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 TERMINAL |
CBBL | FEATURES PROVIDED | ADJUSTABLE TRIP RELEASE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 50.0 AMPERES AC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 500.0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS AND TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 175.0 ALL LOCATIONS |
CPSF | ADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPS | +300.0 TO 350.0 AC ALL LOCATIONS |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 420.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 1500.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
TTQY | TERMINAL TYPE AND QUANTITY | 6 SCREW |