NSN 5925-00-738-7301 of Circuit Breaker - Parts Details
Alternative NSN: 5925007387301 |
Item Name: Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 007387301 |
NCB Code: USA (00) |
Manufacturers: Liebherr Aerospace , Feinmechanische Werke Mainz Gmbh , Honeywell International Inc , Bundesamt Fuer Ausruestung , Kraus And Naimer Gmbh |
ASAP Aviation Procurement, owned and operated by ASAP Semiconductor, is the latest parts procurement platform for the aerospace and aviation industry. Check out high demanding part numbers 7387301, 500396, 25704-281600-05-0 under NSN 5925-00-738-7301 of Circuit Breaker manufactured by Liebherr Aerospace, Feinmechanische Werke Mainz Gmbh, Honeywell International Inc, Bundesamt Fuer Ausruestung, Kraus And Naimer Gmbh.
Federal Supply Class of NSN 5925-00-738-7301 is FSC 5925 contains part details of Circuit Breakers. Quote for your desired part numbers.
Part Number's List for NSN 5925-00-738-7301, 5925007387301
-
Part No Manufacturer Item Name QTY RFQ 7387301 Liebherr Aerospace circuit breaker Avl RFQ 7387301 Feinmechanische Werke Mainz Gmbh circuit breaker Avl RFQ 500396 Honeywell International Inc circuit breaker Avl RFQ 25704-281600-05-0 Bundesamt Fuer Ausruestung circuit breaker Avl RFQ 25704-281600-05-0 Kraus And Naimer Gmbh circuit breaker Avl RFQ
Characteristics Data of NSN 5925007387301MRC Criteria Characteristic ABHP OVERALL LENGTH 4.000 INCHES NOMINAL ABMK OVERALL WIDTH 2.125 INCHES NOMINAL AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.218 INCHES NOMINAL AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 3.500 INCHES NOMINAL AKPX POLE QUANTITY 1 APNQ ARC QUENCHING METHOD AIR AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 UNTHREADED HOLE CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 200.0 AMPERES DC SINGLE LOCATION CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 4000.0 DC SINGLE LOCATION CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 SINGLE LOCATION CPRQ RESET METHOD MANUAL CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE CPRW ACTUATOR FUNCTION RESET CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED DUSTPROOF TTQY TERMINAL TYPE AND QUANTITY 2 THREADED STUD ABKW OVERALL HEIGHT 1.969 INCHES NOMINAL ADTV CASE MATERIAL METAL AEHA DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 1.000 INCHES NOMINAL CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 30.0 DC SINGLE LOCATION CPRJ TRIP RELEASE METHOD MAGNETIC SINGLE LOCATION CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 300.000 NOMINAL AT 125 PCT SINGLE LOCATION AND 40.000 NOMINAL AT 200 PCT SINGLE LOCATION AND 12.000 NOMINAL AT 300 PCT SINGLE LOCATION AND 15.000 NOMINAL AT 400 PCT SINGLE LOCATION CRCF TRIP RELEASE AMBIENT TEMP RATING 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 4.000 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 2.125 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.218 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 3.500 INCHES NOMINAL |
AKPX | POLE QUANTITY | 1 |
APNQ | ARC QUENCHING METHOD | AIR |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 200.0 AMPERES DC SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 4000.0 DC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRW | ACTUATOR FUNCTION | RESET |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF |
TTQY | TERMINAL TYPE AND QUANTITY | 2 THREADED STUD |
ABKW | OVERALL HEIGHT | 1.969 INCHES NOMINAL |
ADTV | CASE MATERIAL | METAL |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.000 INCHES NOMINAL |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 30.0 DC SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 300.000 NOMINAL AT 125 PCT SINGLE LOCATION AND 40.000 NOMINAL AT 200 PCT SINGLE LOCATION AND 12.000 NOMINAL AT 300 PCT SINGLE LOCATION AND 15.000 NOMINAL AT 400 PCT SINGLE LOCATION |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |